Vacuum - Bosch ACS 753 Repair Instructions

A/c service unit
Table of Contents

Advertisement

ACS 753, ACS 763, ACS 863 Service Manual
VACUUM PROCESS
The default vacuum time is 5:00 minutes. When the vacuum process begins, the vacuum pump is activated.
After a 5 second delay, the vacuum, high side and low side inlet solenoids are also activated. When the timer reaches
0 (zero), the vacuum process will stop.
Robert Bosch GmbH
Plumbing and Mechanical
Figure 4-13. Vacuum
93