Plumbing and Mechanical
ss01942
NOTES:
1. Adjust position of ISV liquid and vapor hoses so that the hoses do not contact the center
divider or vacuum pump shelf.
2. Apply Loctite 242 to equivalent to threads.
3. Torque hose fittings to 8.5 ±0.5Nm.
4. Route replacement hoses and tubes in the same positions and places as the original securing
with tie-wraps where appropriate.
SP00D00609
2018-03-26
MANIFOLD ASSEMBLY
OIL DRAIN ASSEMBLY
Figure 4-1. Compressor Interconnection Diagram
ACS 753, ACS 763, ACS 863 Service Manual
COMPRESSOR
76