Description
The I/O card (FUE) FCI2007-A1 provides the remote transmission connections and
the horn outputs. The I/O card (remote transmission) can be used in fire control
panels with card cages FC2030, FC2060, FC2080 and in the FG2020.
The I/O card (RT) FCI2007-A1 has the following features:
One alarm relay
Two monitored horn/alarm outputs
One fault relay
One monitored fault output
One supply output
GPIO input (RT confirmation)
Two programmable inputs/outputs
Configurable behavior in degraded mode:
–
Failsafe behavior in degraded mode
–
Degraded mode behavior in degraded mode
I/O card (RT) FCI2007-A1