Air filter

Air filters are placed in the air-cooling areas each of the head and the controller.
⿎ Effect from deterioration
The air filter soiled with dust may reduce the cooling effect of the air-cooling fan. This may cause the marking performance
to degrade, or failure of the laser marker.
⿎ Replacement interval
• There is a broken part, or contamination that cannot be removed by cleaning.
⿎ Models of replacement parts
For details of purchasing air filters, please contact our sales agency.
Applicable laser marker
LP-400 series
LP-V series
LP-W series
⿎ Steps for cleaning (Daily maintenance) and replacement of air filter
Clean air filters regularly according to the usage environment.
1.
Turn OFF the key switch of the controller, and disconnect the controller power cable.
2.
Loosen the screws of the filter cover panel and remove the panel and filter.
Be aware of keeping the washers attached behind the panel.
LP-400 Series:
2 screws on the head part
Model
LP-AFT20
LP-AFT21
Controller: 2 screws
Washer
Screw
Filter cover panel
Filter
Filter cover panel
Filter type and quantity
• For the head: 2 large-size filters
• For the controller: 1 middle-size filter and 1 small-size filter
• For the head: 1 small-size filter
• For the controller: 1 large-size filter and 1 middle-size filter
Filter
Washer
Washer
Screw
Screw
Filter cover panel
ME-LP400V-OP-6
LP-V/LP-W Series:
1 screw on the head part
Filter
279