12 | Recording and Telemetry
12.2.6 Displaying online recording diagnosis
82 / 108
Bit
Value
4
16
5
32
6
64
7
128
Content of status bits
Name
Bitset
RECORD
Measurement data is re-
corded.
DATAOK
Received data without
error.
BLKOK
All measurement blocks
have been set up cor-
rectly.
STARTED A measurement has
been set up.
("statectrl_ok")
1.
To add a Recording Diagnosis element to a measurement sheet, drag a 'Bit-LED' ele-
ment from the Toolbox and drop it on measurement sheet.
2.
Drag channel 'statectrl_ok' from the Data Area and drop it on the 'Bit-LED' element.
The 'Bit-LED' element shows the state of received channel data in bit-representation. A
green highlighted channel means 0, a red highlighted channel means 1.
– Measurement correctly initialized, but recording threshold(s) not reached: 254
– Measurement correctly initialized, C 60 is recording data: 255
– Values less than 254 indicate an error state
Data Logger C 60
Name
-
-
STARTED
-
Bit cleared
No measurement data will be stored because meas-
urement thresholds are not reached.
Discarding received data because of wrong
timestamps. Check wiring of SYNC signal.
Some measurement blocks have not been set up
correctly.
A measurement is not set up. Either no recording
configuration has been found or logger software
upgrade is not activated.
Bosch Motorsport