Camera part and connector definition
5.2
Connector pin definition
5.2.1
Digital I/O terminal
5.2.2
DC Auto Iris port
5.2.3
Power IN connector
5.2.4
Video output connector
5.2.5
IP/TV switch
5.2.6
Default/reset buttons
12
Siemens Building Technologies
Fire Safety & Security Products
GND
AI2
RS485- / +
COM
AO
GND
Al1
PIN 1
PIN 2
PIN 3
PIN 4
RED: Power +
WHITE: Power -
Video Signal Output
IP
TV
DEFAULT
RESET
1. External alarm input-2
2. Becoming BW/CL enforced input when the Digital
Input Mode is set to BW Mode in the Configuration-
Alarm page
RS485 signal output port for telemetry control
Alarm output port
External alarm input-1
Damp -
Damp +
Drive +
Drive
Power: 12 V DC or 24 V AC
Composite video output
Video out through Ethernet
BNC composite video out for installation purposes
Return to factory default by pressing button for 5
seconds
System re-start