Sony LMT-300 Service Manual page 33

Media block
Hide thumbs Also See for LMT-300:
Table of Contents

Advertisement

Event
Event display
classifi cation
0031
ERROR
DDR MPU ERR
0050
WARNING
SET OVER HEAT
0060
ERROR
FPGA ECC ERR
0061
ERROR
DIMM1 ECC ERR
0072
WARNING
UNFORMAT
0090
ERROR
SAS CTRL1 ERR
0091
ERROR
SAS CTRL2 ERR
0094
ERROR
FPGA ERR
0097
ERROR
FPGA DIMM ERR
0114
WARNING
FAN A1 DEFECT
0115
WARNING
FAN A2 DEFECT
0116
WARNING
FAN B1 DEFECT
0117
WARNING
FAN B2 DEFECT
0118 to
WARNING
HDD<no> WARNING
0124
or ERROR
0133 to
ERROR
HDD<no> FAIL
0139
1000
ERROR
AGENT SERVICE
MISSING.
1002
ERROR
TAMPER
MONITORING
UNAVAILABLE
1004
ERROR
PLAYER
SERVICEMISSING
1005
ERROR
SUBTITLE SERVICE
MISSING
1006
ERROR
DATABASE SER-
VICE MISSING
LMT-300
Description
An error is detected during I
C check of MPU memo-
2
ry.
The abnormal increase in a temperature is detected
inside this unit.
An uncorrectable error occurs in RAID.
An uncorrectable error occurs in SO DIMM on the
PU-131 board.
A logical format is not executed.
An error occurs in the HDD control circuit (IC1) on
the PU-131 board.
An error occurs in the HDD control circuit (IC2) on
the PU-131 board.
An error occurs in FPGA on the PU-131 board.
A data error occurs in SO DIMM on the PU-131
board.
An error occurs in fan 1 of fan unit A.
An error occurs in fan 2 of fan unit A.
An error occurs in fan 1 of fan unit B.
An error occurs in fan 2 of fan unit B.
An error occurs in <no> HDD.
(This unit can be used continuously.)
An error occurs in HDD of a <no> number.
(This unit cannot be used continuously.)
Processing stops due to the logical mismatching of
communication between SMS and this unit.
A tamper-event detector cannot be connected.
Projection stops due to logical mismatching.
Subtitle processing stops due to logical mismatching.
Database processing stops due to logical
mismatching.
Subtitle processing stops due to logical mismatching.
Remedy
Replace the DDR SDRAM
DIMM module of a PU-131
board assembly.
Replace the air fi lter or
adjust the operating
temperature.
Analyze a log and take
measures for the defective
point.
Replace the SO-DIMM
card of a PU-131 board
assembly.
Execute the logical format.
Replace the PU-131 board.
Replace the PU-131 board.
Replace the PU-131 board.
Replace the SO-DIMM
card of a PU-131 board
assembly.
Replace fan 1 of fan unit A.
Replace fan 2 of fan unit A.
Replace fan 1 of fan unit B.
Replace fan 2 of fan unit B.
Use continuously.
Remove HDD of a <no>
number after alternate
HDD is inserted.
Submit the occurrence
date, symptom, and log to
Sony representatives.
Temporary measures:
Restart this unit.
Check the connection of a
CSS harness. Submit the
occurrence date,
symptom, and log to Sony
representatives.
Submit the occurrence
date, symptom, and log to
Sony representatives.
Temporary measures:
Restart this unit.
Submit the occurrence
date, symptom, and log to
Sony representatives.
Temporary measures:
Restart this unit.
Submit the occurrence
date, symptom, and log to
Sony representatives.
Temporary measures:
Restart this unit.
2-5 (E)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents