Sony LMT-300 Service Manual page 32

Media block
Hide thumbs Also See for LMT-300:
Table of Contents

Advertisement

Event
classifi cation
0000
INFORMATION
0004
ERROR
0006
ERROR
0007
ERROR
0008
WARNING
0011
ERROR
0028
WARNING
2-4 (E)
Event display
Description
SHOW START
The CPL verifi cation status of <cplid> failed in
FAILED
the start of projection because it is <Verify
VERIFY:<Verify
Status>.
Status> <cplid>
SHOW START
The CPL validity verifi cation status failed in the
FAILED
start of projection because it is <Validate
VALIDATE:<Validate
Status>.
Status> <cplid>
KDM KEY TYPE
KeyType in KDM of <kdmid> did not exist.
MISSING:<kdmid>
SHOW START
The start of projection failed because CPL
FAILED MISMATCH
ContentAuthenticator of <cplid> does not
CONTENT AUTH
coincide.
<cplid>
SHOW START
The start of projection failed because CPL Key-
FAILED MISMATCH
Type of <cplid> does not coincide with Key-
KEY TYPE <cplid>
Type specifi ed by KDM.
SHOW START
The start of projection failed because the
FAILED.
certifi cate information of MediaBlock is not
TDL ERROR MB
described in TDL of KDM for CPL of <cplid>.
<cplid>
SHOW START
The start of projection failed because the
FAILED.
certifi cate information of projector is not
TDL ERROR PRJ
described in TDL of KDM for CPL of <cplid>.
<cplid>
KDM ALL DELETED
All KDMs are deleted.
SHOW START
The start of projection failed because the
FAILED.
unwrapping of CPL caption fi le of <cplid> has
SUBTITLE UNWRAP
failed.
FAILURE. <cplid>
CC UNWRAP
The unwrapping of closed caption fi le failed.
FAILURE. <cplid>
Mismatch HI/VI
HI/VI channel confi guration labels are different
channel label
in reels
S2S CLIENT
Transfer of S2S client was started.
TRANSFER START
S2S CLIENT
Transfer of S2S client was ended.
TRANSFER END
DCP TRANSFER
Transfer of S2S server was started.
START
DCP TRANSFER
Transfer of S2S server was ended.
END
DCBLOCK Version
DCBLOCK version mismatch
mismatch
MPU BOOT ERR
An error occurs during MPU start.
MPU DDR ERR
An error occurs in the memory of MPU.
PU LOW VLT
The decrease in the supply voltage of the
PU-131 board is detected.
BTRRY DFCT
The voltage decrease in a spare battery for
commercial AC power stop is detected.
PU SRAM ERR
An error occurs in SRAM on the PU-131 board.
THERMO ERR
An error occurs in the temperature sensor on
the PU-131 board.
Remedy
Operation state information
Replace the PU-131 board.
Replace the DDR SDRAM
DIMM module of a PU-131
board assembly.
Check that a detection
switching regulator is not
defective.
Replace the four backup
batteries of two fan units.
Replace the PU-131 board.
Replace the PU-131 board.
LMT-300

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents