Environmental Setting; Environmental Setting Related To Laser Marker - Panasonic LP-310 Operation Manual

Co2 laser marker, lp-300 series
Table of Contents

Advertisement

3-14

Environmental Setting

Set the environments of the laser marker and PC.

3-14-1Environmental Setting Related to Laser Marker

"File" - "ENVIRONMENT" - "Laser Marker"
When selecting the "Laser Marker" in "File", the "Set Up Laser Marker" dialog box is appeared. On this screen,
the following items, Date, Time, Era year, System Offset, and Port are set.
(3)
Click "SET"
Click "CLOSE"
(1) Clock
Set the date, time, and era year of the internal memory of the head are set.
Setting of date and time
Setting of era year
Adjust the clock setting of the laser marker to that of the PC.
The date and time set on the PC are applied only when displaying the image of the current date
and time, etc. The date and time set on the PC are also applied to display the current date and
so on as an image, and perform the test marking. Besides, the date and time set in the laser
CHECK
marker are applied to marking characters in the remote mode.
For the setting method of the date and time of PC, refer to the operation manual of the user's PC.
The following items, Date, Lot, and Expiration, are marked based on the internal clock integrated
in the laser marker.
The internal clock might be deviated caused by the error of the internal parts or degree of the bat-
CHECK
tery drain.
Therefore, be sure to check the time of the internal clock before the operation without fail.
150
:
The setting contents are reflected to this setting software and laser marker.
The change is ignored and the settings are returned to the original condition, and
:
then the dialog box is closed.
:
Click the item to be changed, and change the value using up-down button.
Click the era year and change the value using the keyboard. The settable era year
:
is from 1 to 99. It is changeable using up-down button.
(1)
(2)