Example 2: Hot Mix Asphalt (HMA) silo
nozzle
height
200 mm
tank height
14.0 m
13.0 m
Parameter
Description
1.1
Language Local
1.2
Length Unit
1.3
Nozzle Height
1.4
Tank Height
1.5
Level URV
1.6
Level LRV
1.7
Level Damping
1.8
Application Type
When tank is nearly empty, dip tank and then:
Auto False Echo
4.2.3.9
Suppression Distance
Auto False Echo
4.2.3.8
Suppression
7ML19985JC02
tank diameter
URV
English
m
200
14
13
0
50
Silo2
2 meters less than
dipped distance
Record (will then
default to Use)
SITRANS LR 400 (Solids) – INSTRUCTION MANUAL
The application is to obtain a
3.0 m
level measurement and
corresponding 4 to 20 mA
output proportional to asphalt
levels in a Hot Mix Asphalt
(HMA) silo.
Lower Range value is 0 m, at
the bottom of the silo. Upper
Range value is 13 m
measured from the bottom of
the silo.
Use Auto False-Echo
Suppression when the level
in the silo is low but not
empty. First, when the level is
low, dip the silo to determine
the exact distance. Subtract
2 m from the measured
distance. Then, set Auto
False-Echo Suppression
Distance (4.2.3.9) to this
value.Then set Auto False-
Echo Suppression (P . 4.2.3.8)
to Record. SITRANS LR 400
will automatically revert to
Use for Auto False-Echo
Suppression after about
three seconds.
Value
LCD language setting
meters
200 mm
meters
meters
meters
seconds
application user type (solids with low
reflectivity)
meters (defines the end of the auto false
echo suppression distance)
(learns and then activates auto false
echo suppression)