Bosch Solution 2000 Installation Manual page 90

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

90
en | Access
The user can arm the system but cannot disarm the system. An Arming Report is sent only
after a previous code with the ability to send a Disarming Report disarms the system.
Arming/Disarming Reports
Arming/Disarming Reports are sent to the monitoring station when the user disarms and arms
the system.
Code To Isolate
If one or more User Codes include this option, the method of standard isolating is disabled
and only a User Code with this option in its priority level can isolate zones before arming the
system using the Code to Isolate method. Refer to Isolating zones, page 35.
Notice!
When priority level 4, 6, 12, or 14 is assigned to any User Codes, the Standard Isolating
method no longer operates. Only User Codes with a priority level of 4, 6, 12, or 14 can isolate
zones using the Code to Isolate method.
Master Code Functions
Master Code functions allow those users that have the appropriate priority level to perform
certain supervisory level functions. You can use these functions only when the system is
disarmed.
Notice!
The default Master Code (User Code 1) is 2580. It is possible to program multiple Master
Codes
To access a Master Code function, enter the Master Code and press the corresponding
function digit and the [AWAY] button. The Master Code functions are listed in below table.
Function
0
1
2
3
4
5
6
7
8
9989
Table 12.2: Master Code Functions
See also
2017.10 | 03 | F.01U.298.026
Description
Arm or disarm both areas at the same time
Add, change, and delete User Codes/Remote Radio User Codes
Change domestic phone numbers
Change Telco Arm/Disarm Sequence
Set bypass zones for STAY Mode 2
Turn outputs on and off
Set the date and time
Walk Test Mode
Event Memory Recall Mode
System reset
Master Code Functions, page 51
Installation Guide
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents