3.2.8
Safe Speed Monitor (SSM)
Definition according to EN 61800-5-2:
"The SSM function supplies a safe
output signal to indicate whether the
motor speed is below a specified limit
value."
Not e
S S M is a pure signaling f unction
Unlike other Safety Integrated functions, exceeding the SSM limit value does not result in a
drive-autonomous stop response.
Ex ample of how the function can be used
Example
A centrifuge may only be filled below a
velocity defined by the user.
Details and parameterization
For further details and information on how to parameterize this function, see Section "Safe
Speed Monitor (SSM) (Page 108)".
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Overview of Safety Integrated functions
3.2 Safety Integrated Extended Functions
Po ssible solution
SSM is activated by configuring the Safety Integrated
•
Extended Functions.
The converter safely monitors the centrifuge speed
•
and enables the process to advance to the next step
using the "Status SSM" status bit.
53