2 PRODUCT DESCRIPTION
The order codes for the reduced size vertical mount units with the process bus module are shown below.
Table 2–7: L30 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
L30
-
*
**
- *
*
* - F
BASE UNIT
L30
|
|
|
|
|
CPU
T
|
|
|
|
U
|
|
|
|
V
|
|
|
|
SOFTWARE
00
|
|
|
03
|
|
|
06
|
|
|
07
|
|
|
18
|
|
|
19
|
|
|
24
|
|
|
25
|
|
|
26
|
|
|
27
|
|
|
A0
|
|
|
A3
|
|
|
A4
|
|
|
A6
|
|
|
A7
|
|
|
AI
|
|
|
AJ
|
|
|
AO
|
|
|
AP
|
|
|
AQ
|
|
|
AR
|
|
|
B0
|
|
|
B3
|
|
|
B4
|
|
|
B6
|
|
|
B7
|
|
|
BI
|
|
|
BJ
|
|
|
BO
|
|
|
BP
|
|
|
BQ
|
|
|
BR
|
|
|
C0
|
|
|
C3
|
|
|
C6
|
|
|
C7
|
|
|
CI
|
|
|
CJ
|
|
|
CO
|
|
|
CP
|
|
|
CQ
|
|
|
CR
|
|
|
D0
|
|
|
D3
|
|
|
D4
|
|
|
D6
|
|
|
D7
|
|
|
DI
|
|
|
DJ
|
|
|
DO
|
|
|
DP
|
|
|
DQ
|
|
|
DR
|
|
|
E0
|
|
|
E3
|
|
|
E6
|
|
|
E7
|
|
|
EI
|
|
|
EJ
|
|
|
EO
|
|
|
EP
|
|
|
EQ
|
|
|
ER
|
|
|
F0
|
|
|
F3
|
|
|
F6
|
|
|
F7
|
|
|
FI
|
|
|
FJ
|
|
|
FO
|
|
|
FP
|
|
|
FQ
|
|
|
FR
|
|
|
G0
|
|
|
G3
|
|
|
G6
|
|
|
G7
|
|
|
GI
|
|
|
GJ
|
|
|
GO
|
|
|
GP
|
|
|
GQ
|
|
|
GR
|
|
|
MOUNT/COATING
V
|
|
B
|
|
FACEPLATE/ DISPLAY
F
|
D
|
R
|
A
|
K
|
M
|
Q
|
U
|
L
|
N
|
T
|
V
|
W
|
Y
|
GE Multilin
**
- H
**
- L
**
- N
**
- R
**
Reduced Size Vertical Mount
|
|
|
|
|
Base Unit
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
|
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
|
|
|
|
|
RS485 and Three 10/100Base-T (SFP with RJ45)
|
|
|
|
|
No software options
|
|
|
|
|
IEC 61850
|
|
|
|
|
Phasor measurement unit (PMU)
|
|
|
|
|
IEC 61850 and phasor measurement unit (PMU)
|
|
|
|
|
Synchrocheck and three-pole autoreclose
|
|
|
|
|
Synchrocheck, three-pole autoreclose, and one phasor measurement unit (PMU)
|
|
|
|
|
In-zone transformer protection
|
|
|
|
|
In-zone transformer protection and IEC 61850
|
|
|
|
|
In-zone transformer protection and one phasor measurement unit (PMU)
|
|
|
|
|
In-zone transformer protection, IEC 61850, and one phasor measurement unit (PMU)
|
|
|
|
|
CyberSentry Lvl 1
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
|
|
CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
|
|
CyberSentry Lvl 1 and three-pole autoreclose and synchrocheck
|
|
|
|
|
CyberSentry Lvl 1 and three-pole autoreclose and synchrocheck and one PMU
|
|
|
|
|
CyberSentry Lvl 1 and In-zone transformer protection
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and In-zone transformer protection
|
|
|
|
|
CyberSentry Lvl 1 and phasor measurement unit (PMU) and In-zone transformer protection
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and (PMU) and In-zone transformer protection
|
|
|
|
|
IEEE 1588
|
|
|
|
|
IEEE 1588 and IEC 61850
|
|
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
|
|
IEEE 1588 and phasor measurement unit (PMU)
|
|
|
|
|
IEEE 1588 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
|
|
IEEE 1588 and three-pole autoreclose and synchrocheck
|
|
|
|
|
IEEE 1588 and three-pole autoreclose and synchrocheck and one PMU
|
|
|
|
|
IEEE 1588 and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and IEC 61850 and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and phasor measurement unit (PMU) and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and IEC 61850 and (PMU) and In-zone transformer protection
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
|
|
|
|
|
PRP and IEC 61850
|
|
|
|
|
PRP and PMU
|
|
|
|
|
PRP, IEC 61850, and PMU
|
|
|
|
|
PRP, three-pole autoreclose, and synchrocheck
|
|
|
|
|
PRP, three-pole autoreclose, PMU, and synchrocheck
|
|
|
|
|
PRP and in-zone transformer protection
|
|
|
|
|
PRP, in-zone transformer protection, and IEC 61850
|
|
|
|
|
PRP, in-zone transformer protection, and PMU
|
|
|
|
|
PRP, in-zone transformer protection, IEC 61850, and PMU
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and three-pole autoreclose and synchrocheck
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and three-pole autoreclose and synchrocheck and PMU
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and one PMU and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and PMU and In-zone transformer protection
|
|
|
|
|
IEEE 1588 and PRP
|
|
|
|
|
IEEE 1588, PRP, IEC 61850
|
|
|
|
|
IEEE 1588, PRP, and PMU
|
|
|
|
|
IEEE 1588, PRP, IEC 61850, and PMU
|
|
|
|
|
IEEE 1588, PRP, three-pole autoreclose, and synchrocheck
|
|
|
|
|
IEEE 1588, PRP, three-pole autoreclose, PMU, and synchrocheck
|
|
|
|
|
IEEE 1588, PRP, and in-zone transformer protection
|
|
|
|
|
IEEE 1588, PRP, in-zone transformer protection, and IEC 61850
|
|
|
|
|
IEEE 1588, PRP, in-zone transformer protection, and PMU
|
|
|
|
|
IEEE 1588, PRP, in-zone transformer protection, IEC 61850, and PMU
|
|
|
|
|
PRP and CyberSentry Lvl 1
|
|
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
|
|
PRP, CyberSentry Lvl 1, and PMU
|
|
|
|
|
PRP, CyberSentry Lvl 1, IEC 61850, and PMU
|
|
|
|
|
PRP, CyberSentry Lvl 1, three-pole autoreclose, and synchrocheck
|
|
|
|
|
PRP, CyberSentry Lvl 1, three-pole autoreclose, PMU, and synchrocheck
|
|
|
|
|
PRP, CyberSentry Lvl 1, in-zone transformer protection
|
|
|
|
|
PRP, CyberSentry Lvl 1, in-zone transformer protection, and IEC 61850
|
|
|
|
|
PRP, CyberSentry Lvl 1, in-zone transformer protection, and PMU
|
|
|
|
|
PRP, CyberSentry Lvl 1, in-zone transformer protection, IEC 61850, and PMU
|
|
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and PMU
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and PMU
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, three-pole autoreclose, and synchrocheck
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, three-pole autoreclose, PMU, and synchrocheck
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, in-zone transformer protection
|
|
|
|
|
IEEE 1588 PRP, CyberSentry Lvl 1, in-zone transformer protection, and IEC 61850
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, in-zone transformer protection, and PMU
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, in-zone transformer protection, IEC 61850, and PMU
|
|
|
|
|
Vertical (3/4 rack)
|
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
|
|
|
|
|
English display
|
|
|
|
|
French display
|
|
|
|
|
Russian display
|
|
|
|
|
Chinese display
|
|
|
|
|
Enhanced front panel with English display
|
|
|
|
|
Enhanced front panel with French display
|
|
|
|
|
Enhanced front panel with Russian display
|
|
|
|
|
Enhanced front panel with Chinese display
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
|
|
|
|
Enhanced front panel with Turkish display
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
L30 Line Current Differential System