8.5 Backing up and restoring the configuration of a PLCSIM Advanced instance

8.5
Backing up and restoring the configuration of a PLCSIM Advanced
instance
Backing up and restoring the configuration
As of PLCSIM Advanced V2.0 it is possible to back up and restore a PLCSIM Advanced
instance.
You can create as many backups as you want and store a variety of configurations for a
PLCSIM Advanced instance.
You perform the backup and restore in the TIA Portal as you would in a real CPU.
Backup and restore via the Web server and (simulated) display are not supported.
A backup that was created with PLCSIM Advanced can only be used with
PLCSIM Advanced.
It is not possible to restore the configuration of a real CPU with a backup from
PLCSIM Advanced.
Requirements
● The configuration of a PLCSIM Advanced instance is backed up and restored over the
TCP/IP protocol, Softbus is not supported.
● It is only possible to restore the configuration of a PLCSIM Advanced instance with the
corresponding backup from PLCSIM Advanced.
8.6
Restrictions for file paths
The following restrictions apply for user interfaces which expect a path or a complete file
name as the transfer parameter:
Restrictions for local
paths
Restrictions for net-
work paths
350
Write permissions to system-critical directories such as the Windows direc-
tory (%Windows%) or the program directories (%Program Files%, %Pro-
gram Files (x86)%) are not allowed.
In this case the C++ user interface returns the error code
. In this case the managed user interface returns an
SREC_WRONG_ARGUMENT
exception with the error code
In order to be able to use network paths, you must incorporate them as a
network drive.
Otherwise, the C++ user interface returns the error code
. The managed user interface returns an exception
SREC_WRONG_ARGUMENT
with the error code
RuntimeErrorCode.WrongArgument
RuntimeErrorCode.WrongArgument
Function Manual, 12/2017, A5E37039512-AB
.
.