Eventcallback_Ii_Srec_St_Sricc_Uint32_Uint32_Uint32_Uint32 - Siemens Simatic S7-1500 Function Manual

Hide thumbs Also See for Simatic S7-1500:
Table of Contents

Advertisement

User interfaces (API)
7.8 Data types
7.8.2.8

EventCallback_II_SREC_ST_SRICC_UINT32_UINT32_UINT32_UINT32

Description
Table 7- 366 EventCallback_II_SREC_ST_SRICC_UINT32_UINT32_UINT32_UINT32 - Native C++
Syntax
Parameters
Return values
286
typedef void
(*EventCallback_II_SREC_ST_SRICC_UINT32_UINT32_UINT32_UINT32)(
IInstance* in_Sender,
ERuntimeErrorCode in_ErrorCode, SYSTEMTIME in_SystemTime,
EInstanceConfigChanged in_InstanceConfigChanged,
UINT32 in_Param1,
UINT32 in_Param2,
UINT32 in_Param3,
UINT32 in_Param4
);
IInstance in_Sender:
An interface of the instance that receives this event.
ERuntimeErrorCode in_ErrorCode:
A possible error code.
SYSTEMTIME in_SystemTime:
The virtual system time of the virtual controller at the time when this event
was triggered.
EIn-
UINT32
stanceCon-
in_Param1
figChanged
in_Instance
Con-
figChanged
SRICC_HARDW
-
ARE_SOFTWAR
E CHANGED
SRICC_IP_CH
The ID of the
ANGED
interface
None
UINT32
UINT32
in_Param2
in_Param3
-
-
The new IP
The new sub-
net mask
Function Manual, 12/2017, A5E37039512-AB
UINT32
in_Param4
-
The new
standard
gateway
S7-PLCSIM Advanced

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents