Installing
4.3 Installing Power Modules
4.3.2
Dimension drawings, drilling dimensions for the PM230 Power Module, IP55
The following dimension drawings are not to scale.
Frame sizes FSA ... FSC
Figure 4-5
Table 4-1
Frame size
FSA
FSB
FSC
Table 4-2
Frame size
FSA
FSB
FSC
You can mount the Power Modules without any lateral cooling air clearance. For tolerance reasons,
1)
we recommend a lateral clearance of approx. 1 mm.
66
Dimension drawing, PM230 Power Module IP55, FSA ... FSC
Dimensions
Width
Height
[mm]
[mm]
154
460
180
540
230
620
Drilling dimensions, cooling clearances and fixing
Drilling dimensions [mm]
b
h
132
445
158
524
208
604
Depth [mm]
Without operator
With BOP‑2, IOP‑2 operator panel
panel
249
249
249
Cooling air clearances [mm]
c
Top
Bottom
11
100
100
11
100
100
11
125
125
Converter with the CU230P-2 Control Units
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
or blanking cover
256
256
256
Screws/torque
[Nm]
Lateral
0
4 x M4 / 2.5
1)
0
4 x M4 / 2.5
1)
0
4 x M5 / 3.0
1)