8.3.4 Replacing the SS P/K ASSY (CPS618 P/K)
① Remove the Main Cover (L), (R). For instructions, please refer to "8.1 Preparation"
② Unscrew 4 bind-head screws on the Eject Guide.
For instructions, please refer to "8.3.5 Replacing Scanner ASSY"
③ Remove the Mesh-Cloth.
④ Disconnect 2 connectors (J101, J102) from the SS P/K ASSY (CPS618 P/K)
⑤ Unscrew 2 bind-head screws attached to the SS P/K ASSY (CPS618 P/K), and remove (CPS618 P/K)
⑥ Take the reverse step to attach SS P/K ASSY (CPS618 P/K)
⑦ After replacing the SS P/K ASSY, run the Auto Calibration Test.
MANDATORY
Put the removed Mesh-cloth on
※For instructions, please refer to "8.3.41 Mechanism (M) ASSY Cable Routing"
Tools Needed: Magnetic Philips Screwdriver (No.2)
#26 SS P/K ASSY(CPS618)
Motor Cable
Good Wiring
The motor cable is apart from
the SS Sensor Cable
Connector J101
Connector J102
SS Sensor Cable
Cable clamp
Wrong Wiring
Both cables are too close. Not
clamp together.
REV0 10.02.15
Bind-head
screw
-H8-13-