Connecting Ac Power - Siemens RUGGEDCOM RX5000 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX5000:
Table of Contents

Advertisement

RUGGEDCOM RX5000
Installation Guide
Figure 7: Removing a Power Supply
1. Screws
2. Power Supply
3.
Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
Section 2.2.2

Connecting AC Power

To connect AC power to the device, do the following:
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure
the supplied cover is always installed over high voltage screw-type terminal blocks.
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power
supply terminal block. Damage to the power supply may occur.
NOTE
The terminal block is installed using Philips screws and compression plates, allowing either bare wire
connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable screws, which must be
removed to make connections.
1.
Connect the positive wire from the power source to the live terminal on the terminal block.
Connecting AC Power
2
1
3. Chassis
3
Chapter 2
Installing the Device
11