Reader RF350R with ANT 18 and with ISO transponders (MDS D)
Table 4- 47
Transponder
MDS D124
MDS D127
MDS D160
MDS D324
MDS D421
MDS D422
MDS D424
MDS D425
MDS D428
MDS D460
MDS D521
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 18
Without metal
1)
On metal, distance 15 mm
Flush-mounted in metal;
distance all round 15 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal, distance 10 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
On metal, distance 0 mm
Without metal
On metal, distance 0 mm
Without metal
1)
On metal, distance 15 mm
without metal
on metal, distance 0 mm
flush-mounted in metal;
distance all round 0 mm
Planning the RF300 system
4.3 Installation guidelines
ANT 18 without metal
100
85
85
100
95
60
100
85
100
90
80
100
90
40
100
95
90
100
85
75
100
100
100
95
100
95
??
??
??
ANT 18 mounted in met-
al
(10 mm all-round)
85
75
45
90
85
60
80
75
80
75
65
85
65
20
85
85
80
85
80
75
85
85
95
95
95
95
??
??
??