5.2.3
Pin assignment RF310R special version Scanmode RS-422 interface
Pin
5.2.4
LED operating display
The operational statuses of the reader are displayed by the LEDs. The LED can adopt the
colors green, red or yellow and the statuses off , on , flashing :
Table 5- 5
Color
5.2.5
Ensuring reliable data exchange
The "center point" of the transponder must be situated within the transmission window.
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Pin
Assignment
Device end
8-pin M12
1
+ 24 V
2
- Transmit
3
0 V
4
+ Transmit
5
+ Receive
6
- Receive
7
Unassigned
8
Earth (shield)
LED operating display on the reader
Meaning
Operating voltage present, reader ready for operation
Transponder present
Red LED for error display is activated permanently if correct operation of the reader
cannot be guaranteed (e. g. faulty start, checksum error during operation).
5.2 SIMATIC RF310R with Scanmode
Readers