Chapter 3
Device Management
12
Figure 46: IP Services Form
1. Inactivity Timeout Box    2. Telnet Sessions Allowed Box    3. Web Server Users Allowed Box    4. TFTP Server Box    5. Modbus
Address Box    6. SSH Sessions Allowed Box    7. RSH Server Options    8. IP Forward Options    9. Max Failed Attempts Box   
10. Failed Attempts Window Box    11. Lockout Time Box    12. Apply Button    13. Reload Button
2.
Configure the following parameter(s) as required:
Parameter
Inactivity Timeout
Telnet Sessions Allowed
Web Server Users Allowed
TFTP Server
ModBus Address
92
Description
Synopsis:   1 to 60 or { Disabled }
Default:   5 min
Specifies when the console will timeout and display the login
screen if there is no user activity. A value of zero disables
timeouts. For Web Server users maximum timeout value is limited
to 30 minutes.
Synopsis:   1 to 4 or { Disabled }
Default:   Disabled
Limits the number of Telnet sessions. A value of zero prevents any
Telnet access.
Synopsis:   1 to 4 or { Disabled }
Default:   4
Limits the number of simultaneous web server users.
Synopsis:   { Disabled, Get Only, Enabled }
Default:   Disabled
As TFTP is a very insecure protocol, this parameter allows user to
limit or disable TFTP Server access..
DISABLED - disables read and write access to TFTP Server
GET ONLY - only allows reading of files via TFTP Server
ENABLED - allows reading and writing of files via TFTP Server
Synopsis:   1 to 255 or { Disabled }
Default:   Disabled