Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 511

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

For the offline auto tuning for a PM motor, refer to
Pr.
Name
684
Tuning data unit
C000
switchover
71
Applied motor
C100
80
Motor capacity
C101
81
Number of motor
C102
poles
9
Electronic
C103
thermal O/L relay
83
Rated motor
C104
voltage
84
Rated motor
C105
frequency
707
Motor inertia
C107
(integer)
724
Motor inertia
C108
(exponent)
96
Auto tuning
C110
setting/status
90
Motor constant
C120
(R1)
91
Motor constant
C121
(R2)
Motor constant
92
(L1)/d-axis
C122
inductance (Ld)
Motor constant
93
(L2)/q-axis
C123
inductance (Lq)
94
Motor constant
C124
(X)
82
Motor excitation
C125
current
Torque current/
859
Rated PM motor
C126
current
298
Frequency search
A711
gain
450
Second applied
C200
motor
453
Second motor
C201
capacity
510
5. PARAMETERS
5.13 (C) Motor constant parameters
page
519.
Initial
Setting range
value
0
0
1
0 to 6, 13 to 16, 20, 23, 24,
30, 33, 34, 40, 43, 44, 50,
0
53, 54, 70, 73, 74, 330, 333,
334, 8090, 8093, 8094,
9090, 9093, 9094
*2
0.4 to 55 kW
9999
*3
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
9999
Inverter
*2
0 to 500 A
rated
*3
0 to 3600 A
*1
current
200/
0 to 1000 V
*4
400 V
10 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
0
1
0
11
101
*5
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
*2*5
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 6000 mH, 9999
9999
0 to 400 mH, 9999
0 to 6000 mH, 9999
9999
0 to 400 mH, 9999
*5
9999
0 to 100%, 9999
*2*5
0 to 500 A, 9999
9999
0 to 3600 A, 9999
*2*5
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 32767
9999
9999
0, 1, 3 to 6, 13 to 16, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54, 70, 73, 74, 330,
9999
333, 334, 8090, 8093, 8094,
9090, 9093, 9094
9999
*2
0.4 to 55 kW
9999
*3
0 to 3600 kW
9999
Internal data converted value
The value is indicated in A, Ω, mH, or %.
By selecting a motor, the thermal characteristic and motor
constant of each motor are set.
Set the applied motor capacity.
V/F control
Set the number of motor poles.
V/F control
Set the rated motor current.
Set the rated motor voltage (V).
Set the rated motor frequency (Hz).
The setting value of Pr.3 Base frequency is used.
Set the motor inertia.
9999: The constant value of Mitsubishi Electric motor (SF-PR,
SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500 r/min
series) and so on) is used.
No offline auto tuning
Offline auto tuning is performed without rotating the motor.
Offline auto tuning is performed without rotating the motor (V/F
control, IPM motor MM-CF). (Refer to
Offline auto tuning is performed while rotating the motor.
*3*5
*3*5
*2*5
*3*5
Tuning data (The value measured by offline auto tuning is
automatically set.)
*2*5
9999: The constant value of Mitsubishi Electric motor (SF-PR,
*3*5
SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500 r/min
series) and so on) is used.
*3*5
*3*5
The offline auto tuning automatically sets the gain required for
the frequency search.
The constant value of Mitsubishi Electric motor (SF-PR, SF-
JR, SF-HR, SF-JRCA, SF-HRCA and so on) is used.
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
Set the capacity of the second motor.
V/F control
Description
page
606.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents