MODBUS MEMORY MAP
Address
Description
6703
Load Encroachment Reach
6704
Load Encroachment Angle
6705
Load Encroachment Pickup Delay
6706
Load Encroachment Reset Delay
6707
Load Encroachment Block
6709
Load Encroachment Events
670A
Reserved (6 items)
Trip Output (Read/Write Setting)
6800
Trip Mode
6801
Trip 3-Pole Input1
6802
Trip 3-Pole Input2
6803
Trip 3-Pole Input3
6804
Trip 3-Pole Input4
6805
Trip 3-Pole Input5
6806
Trip 3-Pole Input6
6807
Trip 1-Pole Input1
6808
Trip 1-Pole Input2
6809
Trip 1-Pole Input3
680A
Trip 1-Pole Input4
680B
Trip 1-Pole Input5
680C
Trip 1-Pole Input6
680D
Trip Reclose Input1
680E
Trip Reclose Input2
680F
Trip Reclose Input3
6810
Trip Reclose Input4
6811
Trip Reclose Input5
6812
Trip Reclose Input6
6813
Trip Force 3-Pole
6814
Trip Pilot Priority
6815
Breaker Phase A Open
6816
Breaker Phase B Open
6817
Breaker Phase C Open
6818
Trip Events
6819
Reverse Fault Operand
681A
Trip Delay On Evolving Faults
681B
Reserved (5 items)
Open Pole Detect (1P) (Read/Write Setting)
6820
Open Pole Function
6821
Open Pole Block
6822
Open Pole Voltage Supervision
6823
Open Pole Current Pickup
6825
Open Pole Events
6826
Open Pole Line XC0
6828
Open Pole Line XC1
682A
Open Pole Remote Current Pickup
682B
Reserved (5 items)
Pilot DUTT (1P) (Read/Write Setting)
90
Range
Units
0.02 to 250
ohms
5 to 50
degrees 1
0 to 65.535
s
0 to 65.535
s
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 2
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65.535
s
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 65.535
s
0 to 1
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 30
pu
0 to 1
---
300 to 9999.9
ohms
300 to 9999.9
ohms
0 to 30
pu
0 to 1
---
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
0.01
F001
100
F001
30
0.001
F001
0
0.001
F001
0
1
F300
0
1
F102
0 (Disabled)
1
F001
0
1
F195
0 (Disabled)
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
0.001
F001
0
1
F300
0
1
F300
0
1
F300
0
1
F102
0 (Disabled)
1
F300
0
0.001
F001
0
1
F001
0
1
F102
0 (Disabled)
1
F300
0
1
F102
0 (Disabled)
0.001
F001
50
1
F102
0 (Disabled)
0.1
F003
99999
0.1
F003
99999
0.001
F001
50
1
F001
0