(2) Key functions
The table below shows the functions of the keys that are used for the operations of the positioning operation screen.
6)
7)
8)
9)
10)
11)
1) [Menu] key
Returns to the function selection menu screen.
2) [End] key
Exits the servo amplifier monitor.
3) [Forward] key
Runs the servo motor in the forward rotation (CCW) direction.
4) [Reverse] key
Runs the servo motor in the reverse rotation (CW) direction.
5) Operation key
The displayed key varies depending on the connected servo amplifier.
Item
[Pause] key
[Restart] key
[Clear] key
6) [Motor speed] key
Changes the rotation speed of the servo motor.
7) [Acc/dec time] key
Changes the acceleration/deceleration time constant.
8) [Move distance] key
Changes the distance.
9) [JOG] key
Changes to the JOG operation screen.
➠
■4. JOG operation screen
10) [Without Motor] key
Changes to the motor-less operation screen.
➠
■6. Motor-less operation screen
11) [DO ForcedOutput] key
Changes to the DO forced output screen.
➠
■7. DO forced output screen
12)
13)
Stops the rotation of the servo motor temporarily.
This is displayed only when MELSERVO-J2-Super series or MELSERVO-J2M series is
connected.
Resumes the rotation of the paused servo motor.
This is displayed only when MR-J3-□A series or MR-J4-□A is connected.
Deletes the remaining distance of the paused servo motor.
This is displayed only when MR-J3-□A series or MR-J4-□A is connected.
9.4 Operations of Servo Amplifier Monitor Screens
1)
2)
3)
4)
5)
Description
9