10.2.3.1

optiPoint Analog Adapter

The optiPoint analog adapter allows an analog device (such as, telephone (DTMF only),
group 3 fax, modem, cordless telephone) to be connected to an optiPoint 500 telephone.
The connected analog device can send and receive calls on the interface to the system regard-
less of the connection status of the optiPoint telephone, as long as a B channel is available.
The adapter must always have a
Figure 10-11
optiPoint Analog Adapter
T/R interface properties
Supply current: 30 mA
Busy signal when both B channels are busy
Ring sequence: 2.2
Supports only DTMF with Flash
No ground signaling allowed
Does not support: VoiceMail server with T/R interface, message waiting lamp, dictating
equipment, speaker, announcement device (such as start/stop).
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
local power supply
for operating the connected analog device.
MW6 (RJ11) socket assignments:
Pin
1
2
3
4
5
6
Signal
Free
Free
6
T (Tip)
R (Ring)
Free
Free