Siemens HiPath 3000 Service Manual page 586

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Distribution of the PCM segments
There are 64 time-division multiplex channels available for each PCM segment. Blockages oc-
cur if these are busy. The system cannot execute any more call requests.
To guarantee that the system operates without blocking, make sure when you perform config-
uration that the boards on a PCM segment do not require more than the 64 time-division mul-
tiplex channels that are available. The following table lists the number of time-division multiplex
channels that the different boards require.
Table 4-16
Number of Time-Division Multiplex Channels Required Per Board
Board
CR8N
HXGM3 (without extension
modules for additional DSP
channels)
IVML8
IVML24
SLA8N, SLA16N, and
SLA24N
SLC16/SLC16N
SLMO8, SLMO24
STMD8
TIEL
TMDID8
TML8W
TMS2
TMST1
4-156
Number of time-division multiplex channels required
8
16
8
24
Depends on the number of stations
Depends on the number of mobile telephones logged on
Depends on the number of stations (hosts (master) and clients
(slave))
16
4
8
8
30
24
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 5000

Table of Contents