User-Specific Settings During Boot Up; Starting An Hmi Program During Boot Up - Siemens SINUMERIK 810D Commissioning Manual

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

Configuring the system

2.3 User-specific settings during boot up

2.3
User-specific settings during boot up
2.3
Overview
If an HMI program, e.g., HMI Advanced, is to be started following booting, the settings and
functionality differ from those that apply if the service desktop is to be started.
2.3.1

Starting an HMI program during boot up

Filtering keys
During boot up of an HMI program, keystroke sequences and pressed function keys are
simultaneously filtered. The keystroke sequences and functions that were pressed
simultaneously and are to be filtered can be configured in file E:\Windows\System.ini.
Filtering keystroke sequences:
Section:
Key:
Value:
Init value:
Filtering function keys that were pressed simultaneously:
Section:
Key:
Value:
Init value:
2-12
Note
An attempt to set the service desktop background (as in standard Windows) via the
Control Panel does not affect the service desktop background display, but only the boot
screen display.
MMC103Keyb
SeqAct
<bit mask>
(= keystroke sequences to be filtered, specified in accordance with the comment
in E:\Windows\System.ini)
262143
MMC103Keyb
ConcurrentKeyMask
<bit mask>
(= function keys to be filtered, specified in accordance with the comment in
E:\Windows\System.ini)
255
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0