Over Current Limiter (O.C.L)
The +24 VDC output is limited by Ton MAX Limiter (ON time period of transistor Q100) which is part of
the control circuit. The +5 VP, -5 VDC and +5 VDC outputs have over current limiters provided inside the
voltage regulator.