2. All items to be adjusted
When replacing Main Board, adjustment procedure of
DMD Bias voltage,
C/W index delay,
Sub brightness for Computer 1 input,
Sub contrast for Computer 1 input,
Sub brightness for Y/Pb/Pr 1 input,
Sub brightness for Wireless/Card, (TDP-SW20 Only)
Sub contrast for Wireless/Card,
Altitude,
And, save data to EEPROM
should be applied.
When replacing ENGINE, adjustment procedure of
DMD Bias voltage,
C/W index delay,
And, save data to EEPROM
should be applied.
When replacing DMD, adjustment procedure of
DMD Bias voltage,
And, save data to EEPROM
should be applied.
When replacing C/W, adjustment procedure of
C/W index delay,
And, save data to EEPROM
should be applied.
When replacing C/W Sensor Board, adjustment procedure of
C/W index delay,
And, save data to EEPROM
should be applied.
(TDP-SW20 Only)