Canopy T1/E1 Multiplexer
1.3.2
License Keys
Each Canopy T1/E1 Multiplexer is purchased and shipped as 1-port enabled or 4-port
enabled. You can upgrade any pair of 1-port enabled Canopy T1/E1 Multiplexers through
the purchase and installation of
◦
two keys, one per unit, to transform both to 2-port enabled.
◦
four keys, two per unit, to transform both to 3-port enabled.
◦
six keys, three per unit, to transform both to 4-port enabled.
1.3.3
Power Adapters
For connection to power sources, the 110-volt power supply pictured in
Page
12
and the global adapter set pictured in
purchase of each Canopy T1/E1 Multiplexer.
WARNING!
An external AC surge suppression device must be used with the Canopy
T1/E1 Multiplexer. For infrastructure installations, Canopy Engineering
recommends an AC line surge suppression unit that meets the standard
IEC 801-5 (EN61000-4-5) Maximum Surge Voltage (1.2x50µsec) 6 KV.
The −48 v screw-down adapter for battery backup pictured in
option.
1.4 PRODUCT LABELS
Labels on the Canopy T1/E1 Multiplexer include
◦
ESN — Electronic Serial Number, the Media Access Control (MAC) address
◦
MSN — Model Serial Number, which allows tracking of the product
◦
Factory Configuration, which identifies the product as
−
Master Unit or Slave Unit
−
1-Port Unit or 4-Port Unit
1.5 FUNCTIONAL DESCRIPTION OF THE CANOPY T1/E1 MULTIPLEXER
The Canopy T1/E1 Multiplexer has a LAN Ethernet port, a Canopy Backhaul Module
Ethernet port, and four ports as follows:
◦
up to four available when the unit is configured for the T1 transmission scheme.
◦
up to three available when the unit is configured for the E1 transmission scheme
(to support Canopy BH20 Backhaul link traffic).
Configuration and management are provided using the command line interface (CLI) or
EMS GUI.
Issue 3
Page 18 of 73
T1/E1 Multiplexer FPGA Version 3.4
Figure 4
on Page
Figure 5
September 2004
Figure 3
on
12
are included with the
on Page
13
is an