Simultaneous Ip And Analog Video/Control ("Hybrid" Operation) - Bosch MIC612 Operation Manual

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
5.
6.
7.
8.
9.
5.10
Simultaneous IP and Analog Video/Control ("Hybrid"
Operation)
The figure below illustrates how to configure your system to achieve simultaneous video and
control over both IP and analog connections.
Figure 5.11: System configuration for simultaneous video/control
Number
1
2
3
4
5
Bosch Security Systems
Locate the Brown and Grey wires from the composite cable.
Connect the heater wires Brown and Grey to terminal block HD6 as labelled on the PCB.
The heaters are thermostatically controlled and will automatically turn on at +5 °C (+41
°F) and turn off at +15 °C (+59 °F).
Check all connections.
Close the PSU enclosure.
Reconnect the power supply to the power source.
Description
Connection between MIC camera and BNC T-connector in BNC socket on PCB in
MIC IP PSU
Connection between BNC T-connector and encoder in MIC IP PSU
Connection between BNC T-connector and Bilinx-based control (head-end) system
Connection between Bilinx-based control (head-end) system and Local Area
Network (LAN) (or the "cloud")
Connection between the Local Area Network (LAN) and PC connected to video
monitor
Operation Manual
Install the MIC (standard) PSU | en
2016.03 | 2.1 | F.01U.249.416
27