HP P2000 G3 Cli Reference Manual page 348

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

Table 9
advanced-settings-table properties (continued)
Name
super-cap-
failure
super-cap-
failure-numeric
compact-flash-
failure
compact-flash-
failure-numeric
power-supply-
failure
power-supply-
failure-numeric
fan-failure
fan-failure-
numeric
temperature-
exceeded
temperature-
exceeded-
numeric
partner-notify
partner-notify-
numeric
348 XML API basetype properties
Type
Description
Shows whether the cache policy will change from write-back to write-through
string
when the super-capacitor that provides backup power for cache is not fully
charged or fails.
Disabled: The super-capacitor failure trigger is disabled.
Enabled: The super-capacitor failure trigger is enabled. This is the default.
Numeric equivalents for super-cap-failure values.
string
0: Disabled
4: Enabled
Shows whether the cache policy will change from write-back to write-through
string
when CompactFlash memory is not detected during POST (Power-On Self-Test),
fails during POST, or fails during controller operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled. This is the default.
Numeric equivalents for compact-flash-failure values.
string
0: Disabled
512: Enabled
Shows whether the cache policy will change from write-back to write-through
string
when a power supply fails.
Disabled: The power-supply failure trigger is disabled. This is the default.
Enabled: The power-supply failure trigger is enabled.
Numeric equivalents for power-supply-failure values.
string
0: Disabled
64: Enabled
Shows whether the cache policy will change from write-back to write-through
string
when a fan fails.
Disabled: The fan failure trigger is disabled. This is the default.
Enabled: The fan failure trigger is enabled.
Numeric equivalents for fan-failure values.
string
0: Disabled
128: Enabled
Shows whether the system will shut down a controller when its temperature
string
exceeds the critical operating range.
Disabled: The over-temperature trigger is disabled. This is the default.
Enabled: The over-temperature trigger is enabled.
Numeric equivalents for temperature-exceeded values.
string
0: Disabled
8: Enabled
Shows whether the partner controller will be notified when a trigger condition
string
occurs.
Disabled: Notification is disabled; the partner controller will continue
using its current caching mode. This is the default.
Enabled: Notification is enabled; the partner controller will change to
write-through mode for better data protection.
Numeric equivalents for partner-notify values.
string
0: Disabled
2: Enabled

Hide quick links: