Download Print this page

Sony XYSD723IR User Manual

Ir ptz dome camera

Advertisement

Quick Links

※ Read this manual before using the camera
safety announcements
1.Careful transportation
Transport, storage and installation process, we need to prevent stress, severe vibration and damage to the product
immersion.
2. Be careful installation of dome camera modules
To be especially careful, light up-light down, do not force squeezing movement and the structural components, so as to
avoid the dome camera trouble. For security reason, do not cover the housing is not installed electricity.
3. Power, video cables and control cables
Power cables, video cables and control cables preferable to use shielded cable and is independent of routing, can not
blend together with other cables.
4. Electrical Safety
In use must comply with all electrical safety standards, the PTZ Dome Camera or signal transmission line should work with
high-voltage equipment or cables to maintain a sufficient distance (at least 50 meters), if necessary, do a good job against
lightning, surge and other safeguard procedures.
5. Cleaning
When cleaning the camera housing, please use the dry soft cloth. such as severe dirt, please use neutral cleaner gently
wipe. Do not use strong or with abrasive cleaner, so as not to scratch jacket, affecting image quality.
6. Please strictly sealed to prevent liquid splashing into the PTZ Dome Camera, otherwise it will result in permanent
damage to the device.
7. Do not use the camera when exceed the limits of temperature, humidity. Dome camera use temperature of -10 ℃ to
50 ℃, humidity less than 90%.
8. Do not install the camera near the air-conditioned outlet.
Under such conditions, the lens would be fogging following the state of hydrometer.
By the opening and closing air-conditioner frequently caused the high and low temperature changed.
By the opening and closing door frequently caused the high and low temperature changed.
IR PTZ DOME CAMERA

User Manual

Advertisement

loading

Summary of Contents for Sony XYSD723IR

  • Page 1: User Manual

    IR PTZ DOME CAMERA User Manual ※ Read this manual before using the camera safety announcements 1.Careful transportation Transport, storage and installation process, we need to prevent stress, severe vibration and damage to the product immersion. 2. Be careful installation of dome camera modules To be especially careful, light up-light down, do not force squeezing movement and the structural components, so as to avoid the dome camera trouble.
  • Page 2 Spotlight and other light will cause screen aging. Use the camera toward to strong light for a long time, may be raised CCD of the color filter damage and loss the true color images. Specification Model Number XYSD723IR Image sensor 1/3"SONY CCD Signal mode...
  • Page 3: Function Description

    Function Description IR 7-inch brief intelligent high speed dome camera integration, the main function 1. Set address ID, baud rate, control protocol Any operation commands the camera has its own Dome ID, baud rate, communication protocol, a single camera only to respond with its own Dome ID, baud rate, communication protocol, under the operation of the command.
  • Page 4 illumination to ensure colorful images. In the night illumination can be automatically changed to black and white images show a clear interest. 7. Cruise Can be pre-set cruise preset point, certain preset points, organized in the order required to auto-cruise in the queue, only an external command can be in an indoor speed ball set automatically according to preset points in order to provide the time interval constant movement back and forth.
  • Page 5 Call presets On the keyboard , or other device input preset number , press that button , " call " or "CALL". PTZ preset point will jump to change the previously set position. If the preset number has not been previously set . Then the screen will display " do not set ."...
  • Page 6 " [ ****** ] " This type of menu item indicates that the menu item has a submenu . " < ****** > " The types of menu items that " < > " the value of which is changed number . Can be down about modifying "<>" value inside .
  • Page 7 System info Run setup Serial no.xxxxxxx [preset setup] Address:003 [area instruct] Main Menu Protocol:Pecolo-D [cruise set] Temperature:27 [pttern Set] Version:V1.0 [line scan] Title:xxxxx [full scan] Return Return Exit Exit Main Menu Display setup [system info] Title [display setup] display:<03sec> [control setup] Date display:<On>...
  • Page 8 Main Menu System info [system info] Serial no.xxxxxxx [display setup] Address:003 Move current menu to[system info] [control setup] Protocol:Pecolo-D Press OPEN(iris +) enter [camera setup] Temperature:27 [run setup] Version:V1.0 [other setup] Title:xxxxx [language setup] Return [system restart] Exit [resest] [Exit] Menu Display settings : Users can define various headings are displayed on the monitor .
  • Page 9 Display setup Enter [title setting] sub menu -> moved to the "Dome Title" column Title display:<03sec> -> joystick left and right to select the set the first few characters -> Date display:<On> moved to the "input type" select the current type->ove the character Preset notice:<03sec>...
  • Page 10 Control Settings: Control settings include the following sub-menu items: "[General Settings]": This sub-menu contains some basic ball machine control properties, see the description of the sub-menu. "[Alarm Settings]": This submenu contains dome alarm function attribute settings, see the description of the sub-menu. "[Infrared Settings]": This sub-menu setting control properties of infrared light, infrared ball only support this menu, Ordinary ball is displayed as "[------]."...
  • Page 11 " [ IR Infrared Settings ] Press the OPEN ( iris open + ) into the infrared setting. Move to the menu item, press OPEN ( iris open + ) configuration values for the Control setup corresponding menu item changes - > joystick up and down the [Common setup] menu item to modify the configuration values - >...
  • Page 12 [ Timer Settings ] Press the OPEN (iris open +) into the timer settings. Move to the menu item, press OPEN (iris open +) configuration values for the corresponding menu item changes -> joystick up and down the menu item to modify the Control setup configuration values ->...
  • Page 13 Setup: Run setup includes the following sub-menu items: "[Preset Settings]": Set the preset point. "[Regional Settings]": to set the regional indicative. "[Cruise Settings]": Set the preset cruise scanning. "[Pattern]": Mode Path recording starts. "[Line Scan]": Set between two scans. "[Full Scan]": Set 360 ° scanning. Main Menu Run setup [system info]...
  • Page 14 Press the OPEN (iris open +) into the regional settings. Move Run setup to the menu item, press OPEN (iris open +) configuration [preset setup] values for the corresponding menu item changes -> joystick up [region setup] and down the menu item to modify the configuration values -> [cruise set] press OPEN (iris open +) confirm and save, press CLOSE [pttern Set]...
  • Page 15 Press the OPEN ( iris open + ) into the sequence editor . Move to the menu item, press OPEN ( iris open + ) configuration values for the corresponding menu item changes - > joystick left and right , Edit no.
  • Page 16 " [ Line Scan ] ": Set between two scans. Press the OPEN ( iris open + ) into the line scan . Move to the menu Run setup item, press OPEN ( iris open + ) configuration values for the [preset setup] corresponding menu item changes - >...
  • Page 17 " [ Mobile Tracking ] " : moving object tracking property setting. Run setup [preset setup] Press the OPEN (iris open +) into mobile tracking [region setup] submenu item. Move to the menu item, press OPEN [cruise set] (iris open +) configuration values for the corresponding [pttern Set] menu item changes ->...
  • Page 18 "[Password Protection]": enter the dome menu password. "[Privacy]": Set the privacy zone. (Need camera support, currently only supports SONY, NEWLG cameras privacy protection features. SONY camcorder supports inside the dome menu settings, NEWLG cameras need to set up inside the camera comes with menus.)
  • Page 19 Return exit " [ Privacy ] ": Set the privacy mask area , privacy protection requires camcorder supports privacy function. Currently supported with NEW LG SONY privacy . Other setup Press the OPEN (iris open +) into the privacy [date setup] protection.
  • Page 20 Special preset feature list Summary Table System 65 ~ 99 special preset for the system . Preset number (calling Description system configuration camera type configuration infrared control configuration Start full scan start line scan start preset cruise start pattern scan 72~73 Reserved soft address set...
  • Page 21 23~255 Reserved Zoom Camera Configuration Operation Preset number entry Sub preset number Function Enter system configuration After calling 75 preset , Into the camera menu (camera need with OSD then call the sub Function ) presets within 15 Turn on the camera screen seconds , can achieve Turn Off the camera screen the functionality...
  • Page 22 Reserved 37~255 Reserved IR(Infrared operation Preset number entry Sub preset number Function Enter IR Infraredconfiguration After calling 67 preset , Infrared detection sensitivity set to 1 then call the sub Infrared detection sensitivity set to 2 presets within 15 Infrared detection sensitivity set to 3 seconds , can achieve Infrared detection sensitivity set to 4 the functionality...
  • Page 23 Reserved Reserved Initialization infrared light Set up an infrared brightness is low Set up an infrared brightness is mid Set up an infrared brightness is high Turn on infrared synchronization Turn off infrared synchronization Set into the infrared synchronization time Running function operation Preset number entry Sub preset number...
  • Page 24 then call the sub Start 2 preset cruise presets within 15 Start 3 preset cruise seconds , can achieve Start 4 preset cruise the functionality Start 5 preset cruise described in the Start 6 preset cruise described Start 7 preset cruise functionality .
  • Page 25 … … … … … … … … … - 25 -...