Confirming the Input
4
Switching between Settings
4
Operating a Menu
1.
2.
Exiting the Programming Menu
1.
2.
It is optional to save or not to save the programming data.
1.
2.
5.4

Programming the AMAX System via Keypad

If the keypad is in standby mode, it gets enabled as soon as the first digit of a code is entered.
5.4.1

Setting Date and Time

After the system is powered up, date and time must be set. Otherwise, the system displays a
fault.
1.
2.
3.
P
5.4.2

Deleting a Zone

The zones 1-8 are enabled by default. The zone type for zone 1 is set as 03-delay 1, for zones
2-8 as 01-instant by default. Perform the following steps if you want to delete a zone.
1.
2.
3.
4.
5.
6.
7.
8.
Bosch Sicherheitsysteme GmbH
Press [#] to confirm the input.
Press and hold [*] for 3 seconds to switch between settings.
Operate according to the menu prompt.
Select the menu and enter data for specific programming items according to the display
on the keypad to complete the programming, step by step.
Press [#] to confirm each step.
Complete all programming input by repeating the programming steps above and press [–]
to get back to the current main menu level by level.
Press [–] to get to the EXIT PROG. +SAVE menu.
Select EXIT PROG. +SAVE and press [#] to save the data and to exit the programming
mode.
Select EXIT PROG. UNSAVED and press [#] to exit programming mode without saving
the data.
Make sure that the system is in a disarmed status (the STAY and AWAY indicators are
disabled).
Enter the installer code [1234] + [51] and press [*] to get to CHANGE DATE / TIME.
Enter the current date and time by using the numeric keys and press [*] to confirm.
Date and time are set.
Enter the installer code [1234] + [958] and press [#].
Select 3 ZONE MANAGER and press [#].
Select ADD/DELETE ZONES and press [#].
The system displays the next menu item: INPUT ZONE No.
Enter the number of the zone you want to delete (example: 1) and press [#].
The system displays the next menu item: ZONE NAME INPUT.
Optionally enter a name for the zone. Therefore, the numbers on the text keypad function
as an alphabetical input.
Press [#] to confirm.
The system displays the next menu item: ZONE MODULE SEL.
Select the correct zone module (default is 0-on board zone) and press [#].
The system displays the next menu item: ZONE FUNCTION.
Enter 00 for the zone function 00-not used and press [#].
Programming and Operating the AMAX System | en