Hitachi 3080 G2 Hardware Reference Manual page 69

Hitachi nas platform
Hide thumbs Also See for 3080 G2:
Table of Contents

Advertisement

Procedure
1.
Make sure you have the new hard disk(s) present.
2.
Identify the HDD to be replaced. Using Web Manager GUI, confirm which
HDD is to be replaced.
The LED of the drive that requires replacement is red. If both drive LEDs
are red, see the SMU messages for guidance.
3.
From the node's CLI, issue the command chassis-drive-clean-
configuration --disable --drive drive_letter
Where drive_letter is A or B, the letter of the drive you are replacing.
For example, chassis-drive-clean-configuration --disable --
drive A
This command removes the drive from the RAID group, so you can
continue with the rest of the steps
4.
Remove the HDD:
a. Double-check that you are looking at the intended drive to be
removed.
b. Carefully press the button on the right side of the front of the disk tray
to release the retention latch handle.
Caution: Make sure that you only press the release button for that
one drive.
c. Pull the retention latch handle outward to disengage the disk from the
server.
d. Slide the disk tray out of the chassis.
5.
Insert the replacement HDD:
a. Slide the replacement disk into the chassis until the retention latch
handle starts to close.
b. Press the retention latch handle towards the chassis to secure the disk
in the server. When the disk tray is fully seated, the retention latch
handle will click into the closed position.
Caution: Replace only one HDD at a time. If both HDDs require
replacement, perform this procedure for each HDD.
6.
Replace the bezel .
7.
Log in to the server as the root user.
a. Use SSH to connect to the server using the manager account. By
default, the password for the manager account is nasadmin, but this
password may have been changed.
b. To gain access as root, press Ctrl-D to exit the console, then enter su
–. When you are prompted for the root password, enter it for the root
user account. By default, the password for the root account is
nasadmin, but this password may have been changed.
Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3090 g2

Table of Contents