How to Take Your Temperature
● Take your body temperature as soon as you wake up and while you are still in bed.
( Measurement after getting up or a meal may result an incorrect measurement. )
● Whenever you measure your body temperature by using this Product, please measure
the same point in your mouth
● Measurement should be conducted by using this Product at the same time every
morning to the extent possible
1.
Take Out this Product from the Storage Case. Push the Operation Button at least One Second.
• The power turns on and the display indicates all symbols with a beeper sound.
• The previous value is displayed, and then "
" is displayed.
• When the ambient temperature exceeds 33ºC, the product may display the ambient
temperature due to a warm measurement area.In such cases, turn off the power once and cool the measurement
area, and then take your temperature.
2.
When this Product Displays "Lo" , Place the Measurement Area on Either the Right or Left
Side of the Base of Your Tongue with the Display of this Product upwardly. Hold this Product
with Your Tongue and Shut Your Mouth. Hold this Product with Your Hand to prevent the
Mesurement Point in Your Mouth.
• When a beeper sound goes off in approximately one minute and "ºC" is indicated on the display, an predictive
measurement is successfully completed.Check your body temperature measurement result
• Measurement in an incorrect manner may result an incorrect measurement.
3.
Turn Off the Power by Pushing the Operation Button for at least One Second.
• The power is automatically shut down after a certain period of time lapse even if the operation button is
not pushed.
4.
Put this Product into the Storage Case.
Actual Measurement
* If you want to measure your body temperature strictly, we recommend that you should take an actual body
temperature.Keep on taking your body temperature after the beeper sound in step 2 above. The actual temperature
measurement is successfully completed when the beeper sound goes off once again after approximately 5 minutes
lapse. Check the result of the actual measurement and continue with steps 3 and 4 above.
Transfer your body temperature data in this Product to your smartphone
● If " " is displayed, data transfer to your smartphone is available.
For details, following web site : http://www.toshiba.co.jp/healthcare/bbt/en/index_e.htm
Delete your body temperature data in this Product
● Push the operation button of this Product at least 10 seconds while this Product is powered on.
Upon pushing the operation button even after this Product is powered off, four "□ " are displayed and your body
temperature data in this Product is deleted. If you release the operation button before four "□ " are displayed, the
data will not be deleted.
How to Clean
● Use a dry, soft cloth when removing stains from the product.
● Darker stains may be removed by using a soft cloth slightly moistened with water or alcohol.
●Please observe the following precautions. Cleaning this Product without observing the precautions may cause the trouble of this Product .
• The thermometer is not designed for fully waterproof. When removing stains, please be careful to prevent water and alcohol from entering into
this Product and keep them away from the display.
• Do not soak the measurement area in alcohol or water at than 50ºC or higher to sterilize it. Do not clean the measurement area by using ultrasonic cleaning.
• Do not use thinner, benzine, or abrasive cleaner to clean this Product.
• This Product is waterproofed from measurement area to 5cm away from it only. Keep the operation button and battery to prevent the water.
How to Store
● Dry this Proudct by using a dry cloth before storing it in the storage case.
● If you do not intend to use this Product for a long period, be sure to remove the battery before storage.
● Storage in the places below may cause the trouble of this Product.
• Dusty places. Places subjected to direct sunlight, high-temperature or high-humidity. Places subjected to water or water splashes.
• Places where a corrosive gas is generated. Places subjected to vibration and shock.
Power Off (Blank screen)
Whole symbols on the screen
Piii
Previous value is displayed.
Estimation measurement starts.
Under taking a temperature
PiPi PiPi
Completion of estimation
PiPi
measurement
.
( predictive temperature value )
PiPiPi
Completion of actual
PiPiPi
PiPiPi
temperature measurement
Completion of data deletion
How to replace the battery
Upon pushing the operation button, the remaining battery is indicated in four levels
such as "
>
>
>
" (battery level low). Replace the battery
promptly in accordance with the following procedures when "
Measurement is impossible when "
" is indicated.*Enclosed battery when
you purchase this Product is for the temporary use and it may run out faster than usual.
■ Battery Replacement Procedure (CR2032 lithium battery × 1 pc)
1. Insert a Pointed Object, Such as a Tooth Pick, into the Hole on the Back Side
of this Product (Fig.1), Slide Out the Battery Cover by Using the Pointed
Object (Fig.2), andPull Out the Battery Cover (Fig.3).
2. Remove the Old Battery (Fig.4).
3. Wait for About at least approximately 10 Seconds to Prevent Malfunction of this
Product, And Then Set the New Battery with the "+" Side Upwardly (Fig.5).
Please do not insert a battery directly into this Product. It may cause trouble of this Product.
4. Attach the Battery Cover So That the cover is Inserted into this Product
5. Push the Operation Button and Check that "
" is Displayed.
■ Precautions in Replacing a Battery
● Replacing the battery deletes your body temperature data stored in this Product. Transfer the temperature data to your smartphone
before replacing the battery.
● When disposing of a used battery, please follow all applicable laws and regulations in which it is being used.
● Keep batteries and the battery cover away from small children to prevent their accidental swallowing.
Troubleshooting
Problem
Probable Cause
Scattering in measurement
Placed the measurement area in different
positions for each measurement or opened
values
your mouth during measurement.
A trouble has occurred in this Product during
"Er.03" is displayed.
predictive temperature measurement.
"Er.11 to 19" is displayed.
Measurement has not been conducted in the
correct manner.
"A.Hi" is displayed.
The thermometer has been stored in a place
where the temperature is higher than +40ºC.
"A.Lo" is displayed.
The thermometer has been stored in a place
where the temperature is lower than +10ºC.
"Hi" is displayed.
The measurement result exceeded +42ºC.
"Lo" is displayed.
The measurement result was +33ºC or less.
Other than above cases.
The thermometer has failed.
Nothing is displayed on the
The battery has run out.
display.
The thermometer has failed.
The power can not be turned on.
Battery of this Product is not properly seated.
● For support of this Product , please check our following site.
http://www.toshiba.co.jp/healthcare/bbt/en/index_e.htm
[Display]
" is indicated.
Remaining battery symbol
[Back Side of Main Unit]
Old battery
New battery
Hole (Two points)
(5)
(4)
(1)
(3)
(6)
(2)
(Fig.6).
Wait for
10 seconds.
Remedy
See the " For Correct Measurement " and " How To Take
Your Temperature ".
See the " For Correct Measurement "and " How To Take Your
Temperature ". A
redictive measurement value is not correctly
estimated if the measurement area is taken out of your mouth
during predictive temperature measurement.
Keep on measurement ( for actual temperature measurement )
or turn off the power of this Product once and take your body
temperature again after at least 30 seconds lapse.
See the " For Correct Measurement " and " How To Take Your
Temperature ".Turn off the power of this Product once and take
your body temperature again after at least 30 seconds lapse.
Take your body temperature again after placing this Product in a
+10 to +40ºC environment for at least one minute
Take your body temperature again after placing the thermometer in a
+10 to +40ºC environment for at least one minute .
See the " For Correct Measurement "and " How To Take Your
Temperature ".
See the " For Correct Measurement "and " How To Take Your
Temperature ".
Please visit our website for FAQ
Replace the old battery with a new one. If the power
does not turn on even after the battery has been
replaced, please visit our website for FAQ
If power cannot be turned on, remove the battery once
and insert it again after 5 minutes lapse.

Advertisement

loading