LG 6710 YS Owner's Manual
LG 6710 YS Owner's Manual

LG 6710 YS Owner's Manual

Multi type air conditioner

Advertisement

Multi Type Air Conditioner
OWNER'S MANUAL
MODELS:
6710 YS
6720 YS
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may
help save time and money by explaining proper product
maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused
by misuse of the product.
Prior to installation, this air-conditioning
unit must be submitted for approval by the
utility service which provides electricity
(EN 61000-3 Norm.)

Advertisement

Table of Contents
loading

Summary of Contents for LG 6710 YS

  • Page 1 PRECAUTIONS Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation. LG is not responsible for any damages caused by misuse of the product. Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm.)
  • Page 2: Table Of Contents

    • Contact the authorized service technician for repair or maintenance of this unit. • Contact the installer for installation of this unit. • The air conditioner is not intended for use by young children or invalids without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner.
  • Page 3: Safety Precautions

    Safety Precautions Precautions To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is indicated by the following symbols. WARNING This symbol shows the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property.
  • Page 4 • The air conditioner is not intended for use by young children or infirm persons without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner. When the air filter is to be removed, do not touch the metal parts of the indoor unit.
  • Page 5: Operating Instructions

    Defrost Mode : Lights up during Defrost Mode or Hot Start operation (Heat pump model only) : Lights up during outdoor unit operation. DOOR (Cooling model only) • To operate the room air conditioner, aim the remote control at the signal receptor. Signal receptor Operation indication lamps...
  • Page 6: Operation Mode Selection

    Operating Instructions The remote control transmits the signals to the system. Features of the Remote Control Signal transmitter CANCEL PLASMA Operation Mode Cooling Operation Auto Operation Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( About the remote control on the system START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again.
  • Page 7: Cooling Operation

    How to use the Operation Mode Operating Selection button Instructions Cooling Operation Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
  • Page 8: Auto Operation

    Auto Operation DURING AUTO OPERATION: You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule. If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be done by manually resetting.
  • Page 9: Healthy Dehumidification Operation

    Healthy Dehumidification Operation NATURAL WIND BY THE CHAOS LOGIC DURING HEALTHY DEHUMIDIFICATION OPERATION: If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp.
  • Page 10 Heating Operation(Heat pump model only) NATURAL WIND BY THE CHAOS LOGIC For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
  • Page 11: Jet Cool Operation

    Jet Cool Operation NOTE: During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.
  • Page 12 PLASMA Purification Operation(Optional) PLASMA Air Purifying Operation only PLASMA Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again.
  • Page 13: Additional Features

    Press the Timer Cancel button while CANCEL aiming remote control at the signal receptor. (The timer lamp on the air conditioner and the display will go out.) Delay ON Timer Delay OFFand ON Timer ) disappears from the operation display.
  • Page 14 Vertical Airflow Direction Control The up/down airflow (Vertical Airflow) can be adjusted by using the remote control. Press the Start/Stop button to start the unit. Open the door on the remote control. Press Chaos Swing button and the louvers will swing up and down.
  • Page 15: Forced Operation

    Slide Switch Operation FORCED OPERATION Operation procedures when the remote control can't be used. Open the front panel upward and move the Slide Switch to the Forced Operation position. If you want to stop operation, move the Slide Switch to the Auto Restart or the Remote Control position.
  • Page 16: Care And Maintenance

    Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock. Care and maintenance of the air conditioner Never use any of the followings: • Water hotter than 40°C Could cause deformation and/or discoloration.
  • Page 17 Replacement of Purifying Filter(Option) • Recomended use period : About 2 years Open front panel and remove air filters. Air filter Reinsert air filters and close front panel. Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.
  • Page 18 When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. Operate the air conditioner on Air circulation mode (Refer to page 14) for 2 to 3 hours.
  • Page 19: Troubleshooting Tips

    • Condensation occurs when the airflow from the air conditioner cools the warm room air. • This is the protector of the mechanism. • Wait about three minutes and operation will begin.