(9) Setting the final evaluation output condition
This setting is used to output the result of the final evaluation externally (see page 3-14).
- The final evaluation result is always output to the auxiliary relay C112. When the final
evaluation result is OK, C112 is ON, and when the result is NG, it is OFF. The result of final
evaluation can be externally output by using the auxiliary relay C112.
1. On the [OBJECT TYPE COND] (conditions of object type) menu, move the cursor to r
FINAL OUTPUT COND (final output conditions) and press the SET key.
- The RESULTS OUTPUT (final evaluation conditions) menu will be displayed.
2. Move the cursor to 1 PAGE.NO. (register number) and press the SET key. Move the cursor
3
to YES and press the SET key.
- Items 2 to 5 will be displayed.
2
3
4
5
6
3. Move the cursor to 2 SET POSITION (position to set) and press the SET key.
- Move the cursor to the 0th column of INPUT 0 for logic setting using the up, down, left and
right keys, and press the SET key.
4. Move the cursor to 3 INPUT SIGNAL and press the SET key.
- Select AUXRLY C000 (0 to 127) with the left and right keys, change the setting to "C112"
with the up and down keys, and press the SET key.
- A logic symbol will be displayed in the 0 column of INPUT 0.
5. Move the cursor to 5 OUTPUT SIGNAL and press the SET key.
- Select OUT.Y00 (0 to 15) with the left and right keys. Specify Y00 with the up and down
keys, and press the SET key.
- A symbol indicating an output coil for INPUT 0 will be displayed.
6. Move the cursor to 6 UPPER MENU and press the SET key.
- The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
Continued on the following page
RESULTS OUTPUT
(TYPE00)
1PAGE.NO.
(0~7) REG.NO YES
2SET POSITION
MOVE
3INPUT SIGNAL
AUXRLY C112(0~127) EXT-INP X0(0~6)
TMR TM0(0~7) CNT CN0(0 7)
AN00(0 15) OUT Y00(0 15)
4LOGICAL SYMBOL
5OUTPUT SIGNAL
OUT Y00(0 15) AUXRLY C000(0 127)
TMR TM0(0 7) SET-VL000(000 999)
CNT CN0(0 7) SET-VL000(000 999)
DEL.
6UPPER MENU
[PAGE 0]
0
1
2
INPUT0
LOGIC
INPUT1
3
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
[PAGE0]
0
1
2
INPUT0
C112
LOGIC
PAGE0]
0
1
2
INPUT0
C112
LOGIC
2
4
3
4
5
6
7
OUT
3
4
5
6
7
OUT
3
4
5
6
7
OUT
Y00
3-12

Advertisement

Table of Contents
loading

Table of Contents