When using 12 V DC power supply*
q Loosen the screw of the power cord plug (accessory).
w Connect the cable of the 12 V DC power supply* to the
power cord plug.
Strip 3 mm to 7 mm {1/8" to 9/32"} from the end of the
wire, and twist the stripped part of the wire sufficiently to
avoid short circuit.
Specification of cable (wire): 16 AWG - 24 AWG,
Single core, twisted
• Check whether the stripped part of the wire is not
exposed and is securely connected.
e Tighten the screw of the power cord plug.
r Connect the power cord plug to the 12 V DC power sup-
ply terminal on the rear of the camera.
* FOR UL LISTED MODEL(S), ONLY CONNECT 12 V DC
CLASS 2 POWER SUPPLY.
Important:
• Be sure to use the power cord plug provided with this product.
• Be sure to fully insert the power cord plug into the 12 V DC power supply terminal. Otherwise,
it may damage the camera or cause malfunction.
• When installing the camera, make sure that excessive force is not applied to the power cable.
• Be sure to use an AC adaptor compliant with the Specifications regarding power source and
power consumption (
When using PoE (IEEE802.3af compliant)
Connect a LAN cable (category 5 or better, straight, STP*) between a PoE device (such as a hub)
and the network connector of the camera.
* PAL models only.
Important:
• Use all 4 pairs (8 pins) of the LAN cable.
• The maximum cable length is 100 m {328'}.
• Make sure that the PoE device in use is compliant with IEEE802.3af standard.
• When connecting both the 12 V DC power supply and the PoE device for power supply, PoE
will be used for power supply.
• When disconnecting the LAN cable once, reconnect the cable after around 2 seconds. When
the cable is quickly connected, the power may not be supplied from the PoE device.
p.32).
10BASE T/100BASE-TX
AUDIO OUT
MIC/LINE IN
ACT
LINK
SD CARD/ABF
MONITOR OUT
EXT I/O
GND 4 3 2 1
ALARM IN 1/DAY/NIGHT IN
AUX OUT
ALARM OUT
To 12 V DC
power supply*
(This illustration represents
WV-SP306.)
12 V DC power
cord plug
(accessory)
(GND)
INITIAL
SET
POWER
12V = IN
(12 V DC)