(3)
Close the ADF and check if the positioning
pins fit the holes on the ADF.
[B] Adjustment
If the pins cannot be fitted into the holes, perform the adjustment according to the following procedure.
(1)
Remove the right-hand hinge screw at the
rear side.
(2)
Loosen the left-hand hinge screw at the rear
side.
e-STUDIO163/203 ADJUSTMENT
3 - 46
Fig. 3-39
Fig. 3-40
Fig. 3-41