Craftsman 919.165190 Owner's Manual

Permanently lubricated single stage vertical portable air compressor
Hide thumbs Also See for 919.165190:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual
Permanently Lubricated
Single Stage
Vertical Portable

AIR COMPRESSOR

Model No.
919.165190
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
• Español
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D24588
Rev. 4
9/23/02

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.165190

  • Page 1: Air Compressor

    • Service and Adjustments • Troubleshooting • Repair Parts • Español CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D24588 Rev. 4 9/23/02...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ..........2 SPECIFICATION CHART .
  • Page 3: Safety Guidelines

    SPECIFICATION TABLE Model No. 919-165190 Max. Developed HP Bore 2.38" Stroke 1.35" Voltage-Single Phase 120V/60Hz Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity 25 gallons Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations SAFETY GUIDELINES - DEFINITIONS...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
  • Page 6 HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with protec- it may cause electric shock.
  • Page 7 HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 HAZARD RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    ASSEMBLY Assemble Wheels Contents of Carton It will be necessary 1 - Air Compressor to brace or support 2 - Wheels one side of the air compressor when installing the wheels because 2 - Shoulder Bolts, 3/8-16 the air compressor will have a ten- 2 - Hex Nuts, 3/8-16 dency to tip.
  • Page 11: Installation

    INSTALLATION HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration as dry and well ventilated area.
  • Page 12 Extension Cords Voltage and Circuit Protection Using extension cords is not recom- Refer to the specification table for the mended. The use of extension cords voltage and minimum branch circuit will cause voltage to drop resulting in requirements. power loss to the motor and over- Certain air compressors can be oper- heating.
  • Page 13: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Tank Pressure Gauge Pressure...
  • Page 14: How To Use Your Unit

    Air Compressor Pump (not shown): If the overload protector shuts the Compresses air into the air tank. motor off frequently, check for a pos- Working air is not available until the sible voltage problem. Low voltage compressor has raised the air tank can also be suspected when: pressure above that required at the The motor does not get up to full...
  • Page 15 Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The com- Turn the On/Auto/Off lever to pressor will start. "AUTO" and allow tank pressure Run the compressor for 15 min- to build. Motor will stop when utes. Make sure the drain valve is tank pressure reaches "cut-out"...
  • Page 16: Maintenance

    MAINTENANCE Customer Responsibilities Daily or Before Every Every after each Yearly each hours hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles auto- To Check Safety Valve matically when If the safety valve power is on.
  • Page 17 After the water has been drained, Remove the air filter and make close the drain valve (clockwise). sure it is clean. The air compressor can now be IMPORTANT: Do not operate the stored. compressor with the air filter NOTE: If drain valve is plugged, removed.
  • Page 18: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles auto- Using an adjustable wrench, matically when loosen pressure relief tube nut at power is on. When doing air tank and pressure switch. Maintenance, you may be exposed Carefully move pressure relief to voltage sources, compressed air tube away from check valve.
  • Page 19 Assemble the regulator and ori- To Replace Regulator ent as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Unplug air compressor. Regulator Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator.
  • Page 20: Storage

    STORAGE Before you store the air compressor, Water will con- make sure you do the following: dense in the air tank. If not drained, water will cor- Review the "Maintenance" sec- rode and weaken the air tank caus- tion on the preceding pages and ing a risk of air tank rupture.
  • Page 21: Troubleshooting

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or com- pressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 24 CONTENIDO GARANTÍA ............28 CUADRO DE ESPECIFICACIONES .
  • Page 25: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-165190 Máx. HP desarrollado Diámetro interior 2,38" (60,4 mm) Carrera 1,35" (34,3 mm) Tensión monofásica 120V/60HZ Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 25 Galones (94,6 litros) Presión de corte de entrada Presión de corte de salida SCFM a 40 psig 8,6 Calibre de libras...
  • Page 26 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS LAS ADVERTENCIAS E INSTRUCCIONES DE FUN- CIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
  • Page 27 PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido cada uso.
  • Page 28 PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Su compresor de aire está accionado por electri- Jamás opere el compresor a la intemperie cuan- do está lloviendo o en condiciones de humedad. cidad. Como cualquier otro dispositivo eléctrico impulsado eléctricamente, si no se lo utiliza Nunca opere el compresor sin sus defensas adecuadamente, podría causarle una descar-...
  • Page 29 PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación.
  • Page 30 PELIGRO ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones y podría ocasionarle serias lesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiarícese con los métodos de operación y control del compresor de aire.
  • Page 31: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 32: Ensamblado

    ENSAMBLADO Ensamble de las ruedas Contenido de la caja Será necesario 1- Compresor de aire soportar un lado 2- Ruedas del equipo cuando se instalan las ruedas porque el compresor tenderá a 2- Pernos con resalto, 3/8 - 16 voltearse. 2- Tuercas hexagonales, 3/8 - 16 Fije las ruedas con pernos con 2- Parachoques de goma...
  • Page 33: Instalación

    INSTALACIÓN Asegúrese de que el tomacorriente que CÓMO PREPARAR LA UNIDAD será utilizado tenga la misma configu- ración que el enchufe de conexión a tier- Ubicación del compresor de aire Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. Ver limpia, seca y bien ventilada.
  • Page 34 Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al cuadro de de extensión eléctrica originará una caída especificaciones.
  • Page 35: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 36 Bomba de compresión del aire (no Si el protector de sobrecarga apaga el mostrada): Comprime el aire dentro del motor con mucha frecuencia, verifique si tanque. El aire de trabajo no se encuentra hay algún posible problema de voltaje. disponible hasta que el compresor haya También se puede sospechar de alcanzado a llenar el tanque hasta un nivel bajo voltaje cuando:...
  • Page 37 5. Haga funcionar el compresor durante 15 Cómo poner en marcha: minutos. Asegúrese de que la válvula de Mueva la palanca On/Auto/Off a la posi- drenaje esté abierta y que la presión de ción "AUTO" y deje que se incremente la aire acumulado en el tanque sea mínima.
  • Page 38: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Cada Diariamente Cada Anualmente o luego de de cada cada uso horas horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 39 Una vez drenada el agua, cierre la Retire el filtro de aire y asegúrese de válvula de drenaje que esté (girando en sentido horario). Ahora el limpio. compresor de IMPORTANTE: No opere el compresor aire podrá ser guardado. sin el filtro de aire. NOTA: Si la válvula de drenaje fuera del Si está...
  • Page 40: Servicio Y Ajustes

    SERVICIO Y AJUSTES La unidad cicla Desenrosque la válvula de retención automáticamente girándola hacia la izquierda usando en cuanto la energía eléctrica es una llave de boca de 7/8". Tome conectada. Al efectuar el mantenimien- nota de la orientación para volverla to, usted quedará...
  • Page 41 Ensamble el regulador y oriéntelo de Para reemplazar el regulador acuerdo a lo mostrado. Libere toda la presión del aire del tanque. Vea "Drenaje del tanque" en la sección "Mantenimiento". Desenchufe el equipo. Regulador Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexióN rápida del regulador (si la tiene).
  • Page 42: Almacenaje

    ALMACENAJE El agua se con- Antes de guardar su compresor de aire, densa dentro del asegúrese de hacer lo siguiente: tanque de aire. Si no se drena, ella cor- Revise la sección "Mantenimiento" roerá debilitando la paredes del tanque de las páginas precedentes y ejecute de aire, originando un riesgo de ruptura el mantenimiento programado de de sus paredes.
  • Page 43: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de inten- tar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 44 CORRECCIÓN CAUSA PROBLEMA Si hubiese una caída excesiva de Es normal que ocurra algún La lectura de la presión durante el uso del acceso- descenso en la presión. presión sobre un rio, ajuste el regulador de acuerdo manómetro (si a las instrucciones de la sección viene equipado Operación.
  • Page 45 PROBLEMA CAUSA CORRECCIÓN El motor no fun- Deje enfriar el motor y el interrup- El interruptor de protección des tor de sobrecarga se reajustará ciona. obrecarga del motor se ha abier- automáticamente. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 46 NOTES/NOTAS 50- SP D24588...
  • Page 47 NOTES/NOTAS 51- SP D24588...
  • Page 48 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.