Air Filter Replacement; Troubleshooting; Specifications; Accessories - Samsung Healthy Living CND-501S Instruction Manual

Compressor nebulizer
Table of Contents

Advertisement

Available languages

Available languages

Cleaning the Compressor
Wipe the compressor daily using a soft, slightly water-moistened
cloth.
Note: Do not place Compressor in dishwasher. Any other form of
cleaning or cleaning agents may damage the finish on the unit.

Air Filter Replacement

It is important to change the air filter approximately every 30 days or
when the air filter turns grey.
1) Remove the air filter cover by gently
pulling forward.
2) Discard the gray air filter.
3) Replace with a new clean air filter.
4) Securely reattach the air filter cover to
the unit.
Note: Air filters cannot be cleaned or washed. Do not use cotton or
any other materials. Only use Healthy Living® filters. Do not operate
without a filter.

Troubleshooting

If any abnormality occurs during use, please check and correct the following:
Condition
Unit does not operate when POWER
switch is pressed.
No misting or low rate of misting
7
Cleaning and Maintenance | Troubleshooting
Correction
Check the AC connection to the out-
let
Check that there is medication in the
Nebulizer cup
Check the Nebulizer for damage
Check the position of the purple jet
inside of Nebulizer
Make sure that air tube and other
components are properly attached
Check the air filter and replace if
necessary
Check the air tube and replace if
necessary

Specifications

Power
Power Consumption
Medication Capacity
Particle Size
MMAD
Sound Level
Maximum Capacity of Medication
Average Nebulization Rate
Compressor Pressure Range
Operating Pressure Range
Liter Flow Range
Operating Temperature Range
Operating Humidity Range
Storage Temperature Range
Storage Humidity Range
Dimension (L x W x H)
Weight
Standard Accessories
For purposes of improvement, specifications are subject to change without notice.
Protection against electric shock:
Class II Equipment
Type BF applied parts: Mouthpiece & Masks
Protection against harmful ingress of water: IPX0 (Ordinary)
Degree of safety in the presence of flammable anesthetics or oxygen: No AP/
APG (Not suitable for use in the presence of flammable anesthetics or oxygen)
Mode of operation: continuous
With respect to electric shock, fire and mechanical hazards only
in accordance with UL 1431
�������

Accessories

CNK-510S
(Replacement Nebulizer Kit): Nebulizer, and Air Tube
CNF-520S
(Replacement Filters): 10 pcs
120V, 60Hz
80VA
5 ml
0.5 to 10um
4um
< 60 dBA
13 ml (cc)
Min 0.2 ml/min
30 to 36 psi
8 to 16 psi
6 ~ 8 lpm
50°F to 104°F (10°C to 40°C)
10 to 95% RH
-4°F to 158°F (-20°C to 70°C)
10 to 95% RH
11.4" x 7.2" x 4.2" (290 x x182x 106mm)
4.4 lbs (2.0 kg)
Nebulizer, Air Tube, Adult & Pediatric
Masks, Mouthpiece, Filters (5 pcs)
Specifications