Error Code
Message Information
Details
Action
SEL1306
Message
Details
Action
SEL1308
Message
Details
Action
SEL1501
Message
Details
Action
SEL1502
Message
Details
Action
SEL1504
Message
Details
Action
SEL1506
Message
Details
PXE is one way to boot a system from the network.
Check the network and PXE server configuration.
Invalid boot sector found.
The disk in the drive is not formatted correctly or does not
contain the necessary operating system files.
Replace diskette with a bootable disk.
A time-out occurred while waiting for user to select a boot
source.
The system has failed to boot to an operating system and
needs the user to select a boot source.
Select boot source within the time allowed.
Chassis management controller (CMC) redundancy is lost.
An action or failure has taken place that breaks CMC
redundancy.
Check the CMC network cables and network connections.
Check that CMC firmware versions match.
Chassis management controller (CMC) redundancy is
degraded.
An action or failure has taken place that breaks CMC
redundancy.
Check the CMC network cables and network connections.
Check that CMC firmware versions match.
The chassis management controller (CMC) is not redundant.
Insufficient resources to maintain normal operations.
There is not enough available power for two CMC's to
operate.
Check the overall power consumption and power status.
Lost communications with Chassis Group Member
<number>.
The primary CMC has lost communication with the indicated
member CMC.