Download Print this page

Toshiba e-studio166 Service Handbook page 62

Multifunctional digital systems
Hide thumbs Also See for e-studio166:

Advertisement

Classifi-
Code
cation
407
Fuser
Fuser roller temperature in
ready status
(Side thermistor)
409
Fuser
Fuser roller temperature at
energy saver mode
(Center thermistor)
410
Fuser
Fuser roller temperature
during printing
(Center thermistor/Plain
paper)
411
Fuser
Fuser roller temperature on
standby
(Center thermistor)
413
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
2 - 42
Default
<Accept-
RAM
able
value>
6
M
0: 140°C 1: 145°C
<0-12>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
EUR: 7
M
0: OFF
Other: 0
2: 50°C
<0-13>
4: 70°C
6: 90°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
6
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
6
M
0: 140°C 1: 145°C
<0-12>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
6
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
1
1: 40°C
1
3: 60°C
5: 80°C
7: 100°C
1
1
1

Hide quick links:

Advertisement

loading

This manual is also suitable for:

E-studio163E-studio203E-studio206