When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-200))
(1)
Install the cleaner and developer unit into the equipment.
Note:
Note:
Do not install the toner cartridge.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
(3)
Key in code [200] and press the [START] button.
The display changes as follows.
[ 200 ]
Notes:
A indicates the controlled value of the auto-toner sensor output.
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
C indicates the latest adjustment value.
(4)
After about two minutes, the value B automatically starts changing.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
100%
[ 0 ] [ 5 ]
[ POWER ]
TEST MODE
B
230%
[ START ]
TEST MODE
128
C
230%
TEST MODE
128
3 - 1
04/05
A3
A
A3
200
128
A
A3
200
WAIT
128
e-STUDIO350/352/353/450/452/453
3
ADJUSTMENT