E1 Trunk Timer Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000/SL1100
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-13 : E1 Trunk Timer Setup to define the basic timer setting of E1 Trunk.
Program
Input Data
81
Item
01
Loop Current Detection Time (Loop)
02
Clear Signal (Open Loop) Detection
Time
03
Transmit Clear Signal Time for Forced
Release
04
Receive DP Inter-digit min. Time
16
Pause Time
17
Pulse Dial Break Time
18
Pulse Dial Make Time
19
Pulse Dial Inter-digit Time
20
Receive DP Make min Time
21
Receive DP Make max Time
22
Receive DP Break min Time
23
Receive DP Break max Time
24
Transmit Answer duration Time
25
Transmit Double Answer duration Time
26
Receive Answer min Time
27
Receive Answer max Time
28
Receive Double Answer min Time
29
Receive Double Answer max Time
30
Transmit Seizure Acknowledge duration
Time
31
Receive Seizure Acknowledge min Time 1 ~ 255 (4 ms ~ 1020 ms)
32
Receive Seizure Acknowledge max
Time
33
Transmit Digit Acknowledge duration
Time
34
Receive Digit Acknowledge min Time
35
Receive Digit Acknowledge max Time
36
Receive Meter Pulse min Time
37
Receive Meter Pulse max Time
38
Receive Line Block min Time
2-450
Trunk Port Number
Name

81-13 : E1 Trunk Timer Setup

001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Input Data
1 ~ 255 (16 ms ~ 4080 ms)
1 ~ 255 (16 ms ~ 4080 ms)
1 ~ 255 (16 ms ~ 4080 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (64 ms ~ 16320 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1~255 (4ms ~ 1020ms)
1 ~ 255 (16 ms ~ 4080 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (8 ms ~ 2040 ms)
1 ~ 255 (64 ms ~ 16320 ms)
1 ~ 255 (8 ms ~ 2040 ms)
1 ~ 255 (8 ms ~ 2040 ms)
1 ~ 255 (64 ms ~ 16320 ms)
1 ~ 255 (64 ms ~ 16320 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (4 ms ~ 1020 ms)
1 ~ 255 (64 ms ~ 16320 ms)
Program 81 : Basic Hardware Setup for Trunk
ISSUE 1.0
Default
3 (48 ms)
50 (800 ms)
50 (800 ms)
125 (500 sec)
47 (3008 ms)
15 (60 ms)
10 (40 ms)
50 (800 ms)
3 (12 ms)
19 (76 ms)
5 (20 ms)
26 (104 ms)
38 (304 ms)
32 (2048 ms)
25 (200 ms)
50 (400 ms)
24 (1536 ms)
47 (3008 ms)
25 (100 ms)
25 (100 ms)
75 (300 ms)
25 (100 ms)
25 (100 ms)
75 (300 ms)
25 (100 ms)
75 (300 ms)
32 (2048 ms)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1100

Table of Contents