NOTE: The DBS 576 HD is capable of passing modem speeds up to 31,200 bps or less, depending on the
type and quality of the trunks and facilities used.
AEC to E&M/2-Wire:
AEC to E&M/4-Wire:
BRI to actual line:
T-BRI to S-BRI:
T-PRI to S-PRI:

Signaling Characteristics

Signaling to CO

Dial pulse
Break ratio
Minimum pause
Trunk start signaling

Transmission Specifications

Impedance
Overload level
Insertion Loss
CO trunk to analog station
Analog station to CO trunk
CO trunk to digital station
Digital station to CO trunk
Digital station to digital station
Digital station to analog station
Analog station to digital station
Analog station to analog station

DTMF Frequencies

82
Chapter 6 - Specifications
Digital (ISDN) Ports
Item
Item
Digit
1
2
3
4
5
6
7
8
24,000 bps (maximum) - 9,600 bps (minimum)
(Loss: 0 - 17 dB, 24 AWG)
26,400 bps (maximum) - 14,400 bps (minimum)
(Loss: 0 - 17 dB, 24 AWG)
26,400 bps (maximum)
28,800 bps (maximum)
28,800 bps (maximum)
Specification
8 to 11 pulses per second
58% to 64%
0.7 to 1.0 seconds
Loop or ground start; E&M wink or immediate start
Specification
600 Ohms
600 Ohms
0 dB
0 dB
0 dB
0 dB
6 dB
6 dB
6 dB
6 dB
Frequency (Hz)
700 + 1200
700 + 1340
700 + 1480
760 + 1200
760 + 1340
760 + 1480
860 + 1200
860 + 1340

Advertisement