Initial Measurement Of The New Optical Window - Siemens SIMATIC FS600 Instruction Manual

Table of Contents

Advertisement

5)
Assembling the housing
11.7.2

Initial Measurement of the New Optical Window

After the optical window has been properly mounted, it is essential to perform a
calibration of the optical window. Correct functionality of the scanner cannot be
guaranteed without calibrating the optical window!
Please note: The calibration should be performed with an ambient temperature of 20°C
- 25°C!
Safety Notes: The optical window (dark red) must be clean and in new condition.
Dirty and scratched panes must not be calibrated and used. They would represent
a safety risk since the laser light since the laser light would be weakened under some
circumstances.
When assembling the housing, note that
the two retaining bolts slide into the rubber
sleeves provided for them. To do this,
carefully join the two housing parts on a
level surface.
Retaining bolts
Rubber sleeves
After that, carefully screw in the screws on
the rear wall of the housing, working back
and forth around the circle from screw to
screw.
Remove any finger prints on the optical
window