PARALLEL INP X6
Select the type of input terminal (INPUT) X6.
Input/output condition
EXT-INP
CHNG-IMG-OUT-CAM
CAM-MEAS
2 IMAGES
STROBE OUT
When the strobe output setting is specified as "Y*" and the shutter is opened, the output (Y*)
will be turned ON. When the shutter is closed, the output will be turned OFF.
Y*= Y0 to Y7
Note: When you want to use the strobe output, specify a shutter speed between 1/30 and
1/250 seconds.
Ë Strobe output timing
Shutter
Strobe output
(Y*)
'READY'ON
Set the time to turn ON the READY output signal.
(When the measurement start input source is set to parallel, the object type change signal will
also be parallel, and results will be output as parallel signals.)
At the end of an image capture
At the end of a measurement
The PC function uses the terminal as an external input signal.
- See Chapter 15.
- Every time X6 is switched from OFF to ON, the selected camera will
change. - page 2-4.
- When the object type measurement condition is "CAMERA 1" only.
"CAMERA 2" only, you are not allowed to change the camera used for
output.
- On starting a measurement, if X6 is OFF "CAMERA 1" will execute the
measurement, and if X6 is ON Camera 2 will execute the measurement.
- Before starting a measurement, you must set the following parameters.
Measurement execution:
Image selection: Camera 1 and 2 are through modes.
- When "2 IMAGES (overlap)" is selected, overlap processing will be
executed according to the following timing.
Note: Even if "2 IMAGES (overlap)" has not been selected, and regardless
of which mode Camera 1 and Camera 2 are in, when a trigger (X0:
Manual trigger) is received, the measurement will be executed.
Camera 1
Camera 2
Through image
Overlap input X6
Monitor output
Minimum 4 ms
(1/250 sec.)
Maximum
2 ms
When the controller stops capturing the image, the READY
signal turns ON.
When the controller stops measuring, the READY signal turns
ON.
16-3
Setting the Input/Output Conditions
Setting details
- MEASURE 0 CAMERA 1 conditions
= Gray scale search conditions
- MEASURE 1 CAMERA 2 conditions
= Area conditions (dummy)
Through image
Freeze image
Camera 2
Overlapped image