Is a connected host port's Host Link Status LED off?

Answer
Possible reasons
No
System functioning properly.
Yes
The link is down.

Is a connected port's Expansion Port Status LED off?

Answer
Possible reasons
No
System functioning properly.
Yes
The link is down.

Is a connected port's Network Port Link Status LED off?

Answer
Possible reasons
No
System functioning properly.
Yes
The link is down.
50
Troubleshooting
Actions
No action required.
(see
Link LED
note: page 60)
Check cable connections and reseat if necessary.
Inspect cables for damage.
Swap cables to determine if fault is caused by a
defective cable. Replace cable if necessary.
Verify that the switch, if any, is operating properly. If
possible, test with another port.
Verify that the HBA is fully seated, and that the PCI slot is
powered on and operational.
In SMU, review event logs for indicators of a specific
fault in a host data path component.
Contact an authorized service provider for assistance.
See
Isolating a host-side connection fault
Actions
No action required.
Check cable connections and reseat if necessary.
Inspect cable for damage.
Swap cables to determine if fault is caused by a
defective cable. Replace cable if necessary.
In SMU, review event logs for indicators of a specific
fault in a host data path component.
Contact an authorized service provider for assistance.
See
Isolating a controller module expansion port
connection fault
on page 53.
Actions
No action required.
Use standard networking troubleshooting procedures to
isolate faults on the network.
on page 52.